The Relay,electromagnetic, cataloged under National Stock Number 5945-01-562-0868, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-01-562-0868 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 115.0 AC AND 28.0 DC |
| Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
| Precious Material | GOLD |
| Duty Type | CONTINUOUS |
| Unthreaded Mounting Hole Diameter | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Frequency in Hertz | 400.0 NOMINAL |
| Nominal Operating Current Rating and Type | 10.0 AMPERES DC SINGLE WINDING |
| Time Delay | 6.00 SECONDS NOMINAL FIXED RELEASE TIME |
| Coil Quantity | 1 |
| Environmental Protection | HERMETIC |
| Precious Material and Location | TERMINAL SURFACES GOLD |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Terminal Type and Quantity | 13 PIN ALL FUNCTIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| REBM210J-6001CB | 3/2 Design control — primary reference U.S. Government activity |
NSN 5945-01-562-0868 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-01-562-0868: Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 1.010 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY. 15 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.