PartsTable TECHNICAL DATA SHEET
NSN 5945-01-423-6859Government record, cited

Relay, Electromagnetic5945-01-423-6859

NSN 5945-01-423-6859 · NIIN 014236859
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-423-6859 · 5945014236859 · NIIN 014236859 · 01-423-6859 · FSC 5945 Relays and Solenoids · MIL-PRF-6106/33 · M6106/33-048 · MIL-R-6106/33
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Main Contact Load Current Rating at Maximum Rated Voltage: 400.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
Identification
  • NSN: 5945-01-423-6859
  • NIIN: 014236859
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-423-6859, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-423-6859
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts28.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Main Contact Load Current Rating at Maximum Rated Voltage400.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Unthreaded Mounting Hole Diameter3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating60.0 OHMS NOMINAL FIRST WINDING
Specification/standard Data81349-MIL-R-6106/33 GOVERNMENT SPECIFICATION
Coil Quantity1
Winding Quantity1
Test Data Document81349--6106/33-048 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity6 THREADED STUD ENERGIZING ELEMENT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5945-01-432-1139 POSSIBLE MATCH
RELAY,ELECTROMAGNETIC
Possible match (shared part number)
5945-01-457-9831 POSSIBLE MATCH
RELAY,ELECTROMAGNETIC
Possible match (shared part number)
5945-01-582-0603 POSSIBLE MATCH
RELAY,ELECTROMAGNETIC
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-PRF-6106/33 4/1 Identification reference
U.S. Government activity
M6106/33-048 2/2 Government specification standardization
U.S. Government activity
MIL-R-6106/33 5/9 Secondary reference
U.S. Government activity
Related Parts
5945-01-432-1139POSSIBLE MATCH
RELAY,ELECTROMAGNETIC
5945-01-457-9831POSSIBLE MATCH
RELAY,ELECTROMAGNETIC
5945-01-582-0603POSSIBLE MATCH
RELAY,ELECTROMAGNETIC

Frequently Asked Questions

What is NSN 5945-01-423-6859?

NSN 5945-01-423-6859 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What NSN replaces 5945-01-423-6859?

3 possible matches (shared part number, not a government interchangeability claim): 5945-01-432-1139, 5945-01-457-9831, 5945-01-582-0603. Verify interchangeability with system specifications before substitution.

What are the specifications of 5945-01-423-6859?

Key specifications for 5945-01-423-6859: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 3.380 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 28.0 DC; Fragility Factor: MODERATELY RUGGED. 14 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-423-6859 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com