PartsTable TECHNICAL DATA SHEET
NSN 5945-01-407-1602Government record, cited

Relay, Electromagnetic5945-01-407-1602

NSN 5945-01-407-1602 · NIIN 014071602
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-407-1602 · 5945014071602 · NIIN 014071602 · 01-407-1602 · FSC 5945 Relays and Solenoids · MIL-R-6106/51 · M6106/51-001 · MS27745-1 · MIL-R-83536/18 · MIL-PRF-83536/18
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 3 SLOTTED HOLE SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: TRIANGLE SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Main Contact Load Current Rating at Maximum Rated Voltage: 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
  • Main Contact Load Current Rating at Maximum Rated Voltage: 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
Identification
  • NSN: 5945-01-407-1602
  • NIIN: 014071602
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-407-1602, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-407-1602
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity3 SLOTTED HOLE SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternTRIANGLE SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Main Contact Load Current Rating at Maximum Rated Voltage4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
Main Contact Load Current Rating at Maximum Rated Voltage2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating405.0 OHMS MINIMUM ALL WINDINGS
Features ProvidedLATCHING CONTACTS
Specification/standard Data81349-MIL-R-83536/18 GOVERNMENT SPECIFICATION
Time Delay0.015 SECONDS MAXIMUM FIXED OPERATE TIME
Coil Quantity2
Environmental ProtectionHERMETIC
Cubic Measure2.324 CUBIC INCHES
Winding Quantity2
Operating Voltage Rating and Type at Specified Temp28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
Center to Center Distance Between Mounting Facilities Parallel to Width0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Test Data Document81349-MIL-R-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity16 WIRE HOOK ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-R-6106/51 5/9 Secondary reference
U.S. Government activity
M6106/51-001 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
MS27745-1 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
MIL-R-83536/18 5/9 Secondary reference
U.S. Government activity
MIL-PRF-83536/18 4/1 Identification reference
U.S. Government activity
M83536/18-007M 5/9 Secondary reference
U.S. Government activity
M83536/18-007L 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5945-01-407-1602?

NSN 5945-01-407-1602 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-407-1602?

Key specifications for 5945-01-407-1602: Mounting Facility Type and Quantity: 3 SLOTTED HOLE SINGLE MOUNTING FACILITY; Overall Height: 1.320 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-407-1602 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com