PartsTable TECHNICAL DATA SHEET
NSN 5945-01-338-9242Government record, cited

Relay, Electromagnetic5945-01-338-9242

NSN 5945-01-338-9242 · NIIN 013389242
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-338-9242 · 5945013389242 · NIIN 013389242 · 01-338-9242 · FSC 5945 Relays and Solenoids · MIL-R-6106/19 · MIL-PRF-6106/19 · M6106/19-025
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.396 INCHES MINIMUM AND 1.445 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC RESISTIVE LOAD
Identification
  • NSN: 5945-01-338-9242
  • NIIN: 013389242
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-338-9242, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-338-9242
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Center to Center Distance Between Mounting Facilities Parallel to Length1.396 INCHES MINIMUM AND 1.445 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC INDUCTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage8.0 AMPERES AC MOTOR LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.155 INCHES MINIMUM AND 0.161 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating320.0 OHMS NOMINAL ALL WINDINGS
Specification/standard Data81349-MIL-R-6106/19 GOVERNMENT SPECIFICATION
Time Delay10.00 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME
Coil Quantity1
Environmental ProtectionHERMETIC
Cubic Measure0.910 CUBIC INCHES
Winding Quantity2
Operating Voltage Rating and Type at Specified Temp28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
Test Data Document81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity5 WIRE HOOK ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-R-6106/19 5/9 Secondary reference
U.S. Government activity
MIL-PRF-6106/19 4/1 Identification reference
U.S. Government activity
M6106/19-025 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5945-01-338-9242?

NSN 5945-01-338-9242 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-338-9242?

Key specifications for 5945-01-338-9242: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 0.525 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC; Fragility Factor: MODERATELY RUGGED. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-338-9242 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com