PartsTable TECHNICAL DATA SHEET
NSN 5945-01-332-4412Government record, cited

Relay, Electromagnetic5945-01-332-4412

NSN 5945-01-332-4412 · NIIN 013324412
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-332-4412 · 5945013324412 · NIIN 013324412 · 01-332-4412 · FSC 5945 Relays and Solenoids · MIL-R-6106/10 · MIL-PRF-6106/10 · M6106/10-002
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Nonpile-Up Auxiliary Contact Arrangement: 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 29.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Identification
  • NSN: 5945-01-332-4412
  • NIIN: 013324412
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-332-4412, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-332-4412
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Nonpile-Up Auxiliary Contact Arrangement2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 29.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Center to Center Distance Between Mounting Facilities Parallel to Length1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage60.0 AMPERES AC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.117 INCHES MINIMUM AND 0.179 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Specification/standard Data81349-MIL-R-6106/10 GOVERNMENT SPECIFICATION
Time Delay0.025 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
Coil Quantity1
Cubic Measure14.626 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width1.900 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Test Data Document81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity6 THREADED STUD ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
Auxiliary Contact Maximum Voltage Rating in Volts115.0 AC AND 29.0 DC
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-R-6106/10 5/9 Secondary reference
U.S. Government activity
MIL-PRF-6106/10 4/1 Identification reference
U.S. Government activity
M6106/10-002 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5945-01-332-4412?

NSN 5945-01-332-4412 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-332-4412?

Key specifications for 5945-01-332-4412: Nonpile-Up Auxiliary Contact Arrangement: 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 3.032 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 29.0 DC. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-332-4412 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.