The Relay,electromagnetic, cataloged under National Stock Number 5945-01-304-6773, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Drs Environmental Systems Inc. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-01-304-6773 |
| Primary Part Number | 500K0733 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Manufacturer | Drs Environmental Systems Inc |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 1 TERMINAL SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 240.0 AC |
| Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Time Delay | 0.10 SECONDS MINIMUM AND 10.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| Coil Quantity | 1 |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 24.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| Terminal Type and Quantity | 1 STANDARD TUBE BASE ALL FUNCTIONS |
| Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 500K0733 | Drs Environmental Systems Inc (USA) |
| Reference | Meaning |
|---|---|
| CDB38-30001 | 3/9 Design control — primary reference Te Connectivity Corporation |
| 500K0733 | 5/9 Secondary reference U.S. Government activity |
NSN 5945-01-304-6773 is a Relay,electromagnetic, manufactured by Drs Environmental Systems Inc, classified under FSC 5945, Relays and Solenoids. Status: active.
NSN 5945-01-304-6773 has 1 manufacturer part number on file: 500K0733 (Drs Environmental Systems Inc).
Key specifications for 500K0733: Mounting Facility Type and Quantity: 1 TERMINAL SINGLE MOUNTING FACILITY; Main Contact Maximum Voltage Rating in Volts: 240.0 AC; Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC RESISTIVE LOAD; Duty Type: CONTINUOUS. 10 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.