PartsTable TECHNICAL DATA SHEET
NSN 5945-01-291-5511Government record, cited

Relay, Electromagnetic5945-01-291-5511

NSN 5945-01-291-5511 · NIIN 012915511
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-291-5511 · 5945012915511 · NIIN 012915511 · 01-291-5511 · FSC 5945 Relays and Solenoids · MIL-R-6106/46 · M6106/46-001
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Nonpile-Up Auxiliary Contact Arrangement: 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 200.0 AC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.927 INCHES MINIMUM AND 3.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Identification
  • NSN: 5945-01-291-5511
  • NIIN: 012915511
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-291-5511, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-291-5511
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Nonpile-Up Auxiliary Contact Arrangement6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts200.0 AC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Center to Center Distance Between Mounting Facilities Parallel to Length3.927 INCHES MINIMUM AND 3.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage120.0 AMPERES AC RESISTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage120.0 AMPERES AC INDUCTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage80.0 AMPERES AC MOTOR LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.208 INCHES MINIMUM AND 0.228 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Auxiliary Contact Load Current Rating at Maximum Rated Voltage1.0 AMPERES AC AND 1.0 AMPERES DC LAMP LOAD
Auxiliary Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
Auxiliary Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES AC AND 5.0 AMPERES DC INDUCTIVE LOAD
Specification/standard Data81349-MIL-R-6106/46 GOVERNMENT SPECIFICATION
Coil Quantity1
Environmental ProtectionHERMETIC
Cubic Measure73.130 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width2.833 INCHES MINIMUM AND 2.853 INCHES MAXIMUM SINGLE MOUNTING FACILITY IN
Test Data Document81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity9 THREADED STUD CONTACTS
Terminal Type and Quantity1 CONNECTOR, RECEPTACLE ENERGIZING ELEMENT
Nonpile-Up Main Contact Arrangement3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-R-6106/46 4/1 Identification reference
U.S. Government activity
M6106/46-001 2/2 Government specification standardization
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-291-5511?

NSN 5945-01-291-5511 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-291-5511?

Key specifications for 5945-01-291-5511: Nonpile-Up Auxiliary Contact Arrangement: 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 4.220 INCHES MINIMUM AND 4.280 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 200.0 AC. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-291-5511 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.