PartsTable TECHNICAL DATA SHEET
NSN 5945-01-248-8314Government record, cited

Relay, Electromagnetic5945-01-248-8314

NSN 5945-01-248-8314 · NIIN 012488314
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-248-8314 · 5945012488314 · NIIN 012488314 · 01-248-8314 · FSC 5945 Relays and Solenoids · 67REV4-24DC-SCO · FRL 264 D024/04CV-01 · 596-208
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 120.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Arc Quenching Method: AIR
  • Precious Material: GOLD AND SILVER
  • Main Contact Load Current Rating at Maximum Rated Voltage: 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
Identification
  • NSN: 5945-01-248-8314
  • NIIN: 012488314
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-248-8314, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-248-8314
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts120.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Arc Quenching MethodAIR
Precious MaterialGOLD AND SILVER
Main Contact Load Current Rating at Maximum Rated Voltage3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Winding DC Resistance Rating650.0 OHMS NOMINAL SINGLE WINDING
Time Delay0.013 SECONDS MAXIMUM FIXED OPERATE TIME
Time Delay0.01 SECONDS MAXIMUM FIXED RELEASE TIME
Coil Quantity1
Environmental ProtectionDUSTPROOF
Precious Material and LocationCONTACT SURFACES GOLD AND CONTACTS SILVER
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Terminal Type and Quantity14 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
67REV4-24DC-SCO 3/9 Design control — primary reference
Sigma Instruments Inc
FRL 264 D024/04CV-01 5/9 Secondary reference
Fujitsu America Inc
596-208 5/9 Secondary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5945-01-248-8314?

NSN 5945-01-248-8314 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-248-8314?

Key specifications for 5945-01-248-8314: Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY; Overall Height: 1.264 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 120.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-248-8314 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com