PartsTable TECHNICAL DATA SHEET
NSN 5945-01-248-2208Government record, cited

Relay, Electromagnetic5945-01-248-2208

NSN 5945-01-248-2208 · NIIN 012482208
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-248-2208 · 5945012482208 · NIIN 012482208 · 01-248-2208 · FSC 5945 Relays and Solenoids · M39016/25-032L · J431D-18PL
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Overall Diameter: 0.370 INCHES MAXIMUM IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 100.0 MILLIAMPERES DC LAMP LOAD
  • Main Contact Load Current Rating at Maximum Rated Voltage: 200.0 MILLIAMPERES DC INDUCTIVE LOAD
  • Main Contact Load Current Rating at Maximum Rated Voltage: 600.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Coil Quantity: 1
Identification
  • NSN: 5945-01-248-2208
  • NIIN: 012482208
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-248-2208, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 11 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-248-2208
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Overall Diameter0.370 INCHES MAXIMUM IN
Main Contact Load Current Rating at Maximum Rated Voltage100.0 MILLIAMPERES DC LAMP LOAD
Main Contact Load Current Rating at Maximum Rated Voltage200.0 MILLIAMPERES DC INDUCTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage600.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Coil Quantity1
Environmental ProtectionHERMETIC AND VIBRATION RESISTANT
Operating Voltage Rating and Type at Specified Temp18.0 VOLTS DC 125 DEG CELSIUS SINGLE WINDING
Terminal Type and Quantity8 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
M39016/25-032L 2/2 Government specification standardization
U.S. Government activity
J431D-18PL 5/1 Secondary reference
Teledyne Defense Electronics, Llc Dba Teledyne Relays Div Https://www.teledyne.com/what-We-Do/
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-248-2208?

NSN 5945-01-248-2208 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-248-2208?

Key specifications for 5945-01-248-2208: Overall Height: 0.952 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Overall Diameter: 0.370 INCHES MAXIMUM IN; Main Contact Load Current Rating at Maximum Rated Voltage: 100.0 MILLIAMPERES DC LAMP LOAD. 11 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-248-2208 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com