PartsTable TECHNICAL DATA SHEET
NSN 5945-01-244-3325Government record, cited

Relay, Electromagnetic5945-01-244-3325

NSN 5945-01-244-3325 · NIIN 012443325
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-244-3325 · 5945012443325 · NIIN 012443325 · 01-244-3325 · FSC 5945 Relays and Solenoids · 10066532-101 · HGWM52112N00
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 500.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Arc Quenching Method: AIR
  • Main Contact Load Current Rating at Maximum Rated Voltage: 5.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Storage Type: GENERAL PURPOSE WAREHOUSE
Identification
  • NSN: 5945-01-244-3325
  • NIIN: 012443325
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-244-3325, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-244-3325
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts500.0 DC
Fragility FactorMODERATELY RUGGED
Arc Quenching MethodAIR
Main Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Winding DC Resistance Rating220.0 OHMS NOMINAL ALL WINDINGS
Features ProvidedLATCHING CONTACTS
Time Delay0.001 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
Coil Quantity2
Environmental ProtectionDUSTPROOFDUSTPROOF
Cubic Measure0.207 CUBIC INCHES
Winding Quantity22
Operating Voltage Rating and Type at Specified Temp5.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
MaterialPLASTIC CASE
Terminal Type and Quantity6 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
10066532-101 3/2 Design control — primary reference
U.S. Government activity
HGWM52112N00 5/9 Secondary reference
Cp Clare Corp North American Sales Operations
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-244-3325?

NSN 5945-01-244-3325 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-244-3325?

Key specifications for 5945-01-244-3325: Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY; Overall Height: 0.345 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 500.0 DC; Fragility Factor: MODERATELY RUGGED. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-244-3325 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com