PartsTable TECHNICAL DATA SHEET
NSN 5945-01-240-5261Government record, cited

Relay, Electromagnetic5945-01-240-5261

NSN 5945-01-240-5261 · NIIN 012405261
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-240-5261 · 5945012405261 · NIIN 012405261 · 01-240-5261 · FSC 5945 Relays and Solenoids · FC-404-61 · 157-12C200 · FC-404-61 · FC-404-61
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
Identification
  • NSN: 5945-01-240-5261
  • NIIN: 012405261
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-240-5261, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-240-5261
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity4 THREADED STUD(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Center to Center Distance Between Mounting Facilities Parallel to Length1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Thread DirectionRIGHT-HAND SINGLE MOUNTING FACILITY
Nominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY IN
Time Delay0.02 SECONDS MAXIMUM FIXED RELEASE TIME
Time Delay0.05 SECONDS MAXIMUM FIXED OPERATE TIME
Coil Quantity1
Environmental ProtectionHERMETIC
Cubic Measure3.785 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width0.687 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Thread Class2A SINGLE MOUNTING FACILITY A
Thread Quantity Per Inch32 SINGLE MOUNTING FACILITY
Terminal Type and Quantity14 PRINTED CIRCUIT ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
FC-404-61 3/9 Design control — primary reference
Struthers-Dunn Inc.
157-12C200 C/1 Advisory reference — outside the item-of-supply concept
Midland-Ross Corp Midtex Div
FC-404-61 C/1 Advisory reference — outside the item-of-supply concept
Te Connectivity Corporation
FC-404-61 5/9 Secondary reference
Struthers-Dunn Inc

Frequently Asked Questions

What is NSN 5945-01-240-5261?

NSN 5945-01-240-5261 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-240-5261?

Key specifications for 5945-01-240-5261: Mounting Facility Type and Quantity: 4 THREADED STUD(S) SINGLE MOUNTING FACILITY; Overall Height: 2.188 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-240-5261 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com