PartsTable TECHNICAL DATA SHEET
NSN 5945-01-227-4635Government record, cited

Relay, Electromagnetic5945-01-227-4635

NSN 5945-01-227-4635 · NIIN 012274635
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-227-4635 · 5945012274635 · NIIN 012274635 · 01-227-4635 · FSC 5945 Relays and Solenoids · P069651-01 · 7012-L8-KN
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 30.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 15.0 AMPERES DC RESISTIVE LOAD
Identification
  • NSN: 5945-01-227-4635
  • NIIN: 012274635
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-227-4635, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-227-4635
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts240.0 AC AND 30.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Center to Center Distance Between Mounting Facilities Parallel to Length2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC AND 15.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Frequency in Hertz60.0 NOMINAL
Time Delay1.00 SECONDS MINIMUM AND 300.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
Coil Quantity1
Environmental ProtectionDUSTPROOF
Cubic Measure32.874 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp110.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width2.812 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Terminal Type and Quantity8 SCREW ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
P069651-01 5/9 Secondary reference
Coen Company, Inc.
7012-L8-KN 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-227-4635?

NSN 5945-01-227-4635 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-227-4635?

Key specifications for 5945-01-227-4635: Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 4.520 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 30.0 DC; Fragility Factor: MODERATELY RUGGED. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-227-4635 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com