Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 600.0 AC AND 100.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: DIAGONAL SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Main Contact Load Current Rating at Maximum Rated Voltage: 5.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
Identification
  • NSN: 5945-01-200-6316
  • NIIN: 012006316
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-200-6316, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-200-6316
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 SLOTTED HOLE SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts600.0 AC AND 100.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternDIAGONAL SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Main Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Frequency in Hertz60.0 NOMINAL
Center to Center Distance Between Mounting Facilities Parallel to Height2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Coil Quantity1
Environmental ProtectionDUSTPROOF
Cubic Measure16.062 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
MaterialPLASTIC CASE
Terminal Type and Quantity6 SCREW ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
Purpose for Which DesignedGENERAL
Mounting Slot Width0.201 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5340-01-205-8969622348 POSSIBLE MATCH
CLIP,RETAINING
Possible match (shared part number)Eaton Aerospace, Llc Dba Jackson South
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
2180FE20AA 3/9 Design control — primary reference
Telemecanique Inc
6223-48 5/2 Secondary reference
U.S. Government activity
6223-48 5/9 Secondary reference
Air Dry Co of America, Llc
Related Parts
5340-01-205-8969POSSIBLE MATCH
CLIP,RETAINING
622348

Frequently Asked Questions

What is NSN 5945-01-200-6316?

NSN 5945-01-200-6316 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What NSN replaces 5945-01-200-6316?

1 possible match (shared part number, not a government interchangeability claim): 5340-01-205-8969. Verify interchangeability with system specifications before substitution.

What are the specifications of 5945-01-200-6316?

Key specifications for 5945-01-200-6316: Mounting Facility Type and Quantity: 2 SLOTTED HOLE SINGLE MOUNTING FACILITY; Overall Height: 2.688 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 600.0 AC AND 100.0 DC; Fragility Factor: MODERATELY RUGGED. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-200-6316 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com