PartsTable TECHNICAL DATA SHEET
NSN 5945-01-181-1591Government record, cited

Relay, Electromagnetic5945-01-181-1591

NSN 5945-01-181-1591 · NIIN 011811591 · Part number 9050-JCK-11-120
Schneider Electric Usa, Inc. · FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components · CAGE 56365
Government record, cited
NSN 5945-01-181-1591 — this item is cataloged by the U.S. Government under National Stock Number 5945-01-181-1591. Manufacturer of record part number: 9050-JCK-11-120.
Also searched as  5945-01-181-1591 · 5945011811591 · NIIN 011811591 · 01-181-1591 · FSC 5945 Relays and Solenoids · CAGE 56365 · 9050-JCK-11-120 · 8501-JCK-11-120 · 9050-JCK-11-120V
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Arc Quenching Method: AIR
  • Precious Material: SILVER
  • Main Contact Load Current Rating at Maximum Rated Voltage: 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
Identification
  • NSN: 5945-01-181-1591
  • NIIN: 011811591
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 9050-JCK-11-120
  • Manufacturer: Schneider Electric Usa, Inc.
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-181-1591, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Schneider Electric Usa, Inc.. Government technical data includes 21 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-181-1591
Primary Part Number9050-JCK-11-120
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
ManufacturerSchneider Electric Usa, Inc.
StatusACTIVE
Mounting Facility Type and Quantity1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts240.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Arc Quenching MethodAIR
Precious MaterialSILVER
Main Contact Load Current Rating at Maximum Rated Voltage5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Frequency in Hertz60.0 NOMINAL
Features ProvidedPOLARIZED
Time Delay0.10 SECONDS MINIMUM AND 10.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
Time Delay0.125 SECONDS MAXIMUM FIXED RELEASE TIME
Coil Quantity1
Precious Material and LocationCONTACTS SILVER
Cubic Measure16.219 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
MaterialSILVER CONTACT
Terminal Type and Quantity1 STANDARD TUBE BASE ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
9050-JCK-11-120 PRIMARY Schneider Electric Usa, Inc. (USA)
Reference documents
ReferenceMeaning
8501-JCK-11-120 5/9 Secondary reference
Schneider Electric Usa, Inc.
9050-JCK-11-120V C/1 Advisory reference — outside the item-of-supply concept
Schneider Electric Usa, Inc.
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-181-1591?

NSN 5945-01-181-1591 is a Relay,electromagnetic, manufactured by Schneider Electric Usa, Inc., classified under FSC 5945, Relays and Solenoids. Status: active.

What part numbers are listed for NSN 5945-01-181-1591?

NSN 5945-01-181-1591 has 1 manufacturer part number on file: 9050-JCK-11-120 (Schneider Electric Usa, Inc.).

What are the specifications of 9050-JCK-11-120?

Key specifications for 9050-JCK-11-120: Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY; Overall Height: 4.030 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-181-1591 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com