PartsTable TECHNICAL DATA SHEET
NSN 5945-01-169-7941Government record, cited

Relay, Electromagnetic5945-01-169-7941

NSN 5945-01-169-7941 · NIIN 011697941
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-169-7941 · 5945011697941 · NIIN 011697941 · 01-169-7941 · FSC 5945 Relays and Solenoids · M5757/10-064 · MIL-R-5757/10 · MIL-DTL-5757/10 · 3N79 · 3SAE2107A2
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 THREADED STUD(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Mounting Facility Pattern: DIAGONAL SINGLE MOUNTING FACILITY
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Winding DC Resistance Rating: 495.0 OHMS MINIMUM AND 770.0 OHMS MAXIMUM SINGLE WINDING
Identification
  • NSN: 5945-01-169-7941
  • NIIN: 011697941
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-169-7941, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-169-7941
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 THREADED STUD(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Mounting Facility PatternDIAGONAL SINGLE MOUNTING FACILITY
Center to Center Distance Between Mounting Facilities Parallel to Length1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Winding DC Resistance Rating495.0 OHMS MINIMUM AND 770.0 OHMS MAXIMUM SINGLE WINDING
Thread DirectionRIGHT-HAND SINGLE MOUNTING FACILITY
Nominal Thread Size0.086 INCHES SINGLE MOUNTING FACILITY IN
Specification/standard Data81349-MIL-R-5757/10 GOVERNMENT SPECIFICATION
Time Delay0.006 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
Coil Quantity1
Environmental ProtectionHERMETIC AND SHOCK RESISTANT AND VIBRATION RESISTANT
Cubic Measure0.528 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width0.163 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Thread Class2A SINGLE MOUNTING FACILITY A
Test Data Document81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Thread Quantity Per Inch56 SINGLE MOUNTING FACILITY
Terminal Type and Quantity8 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
M5757/10-064 2/2 Government specification standardization
U.S. Government activity
MIL-R-5757/10 5/9 Secondary reference
U.S. Government activity
MIL-DTL-5757/10 4/1 Identification reference
U.S. Government activity
3N79 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
3SAE2107A2 C/1 Advisory reference — outside the item-of-supply concept
General Electric Company
3SAE2107A2 C/1 Advisory reference — outside the item-of-supply concept
General Electric Co Electronic Components Division of Electronic Atomic and Defense Systems Group
5945011697941 6/9 Informative reference only
E.c.a Etablissement Central Des Approvisionnements Des Forces Armees Royales

Frequently Asked Questions

What is NSN 5945-01-169-7941?

NSN 5945-01-169-7941 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-169-7941?

Key specifications for 5945-01-169-7941: Mounting Facility Type and Quantity: 2 THREADED STUD(S) SINGLE MOUNTING FACILITY; Overall Height: 1.085 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Mounting Facility Pattern: DIAGONAL SINGLE MOUNTING FACILITY. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-169-7941 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com