PartsTable TECHNICAL DATA SHEET
NSN 5945-01-142-9545Government record, cited

Relay, Electromagnetic5945-01-142-9545

NSN 5945-01-142-9545 · NIIN 011429545
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-142-9545 · 5945011429545 · NIIN 011429545 · 01-142-9545 · FSC 5945 Relays and Solenoids · PR1516-2 · 0-171-11 · PR1516-2
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY
  • Duty Type: CONTINUOUS
  • Unthreaded Mounting Hole Diameter: 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Frequency in Hertz: 50.0 MINIMUM AND 60.0 MAXIMUM
  • Coil Quantity: 1
  • Winding Quantity: 1
Identification
  • NSN: 5945-01-142-9545
  • NIIN: 011429545
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-142-9545, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 11 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-142-9545
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Mounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
Duty TypeCONTINUOUS
Unthreaded Mounting Hole Diameter0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Frequency in Hertz50.0 MINIMUM AND 60.0 MAXIMUM
Coil Quantity1
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Terminal Type and Quantity4 SCREW ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
PR1516-2 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
0-171-11 5/9 Secondary reference
U.S. Government activity
PR1516-2 3/9 Design control — primary reference
Te Connectivity Corporation

Frequently Asked Questions

What is NSN 5945-01-142-9545?

NSN 5945-01-142-9545 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-142-9545?

Key specifications for 5945-01-142-9545: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 2.125 INCHES MAXIMUM IN; Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY; Duty Type: CONTINUOUS. 11 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-142-9545 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com