PartsTable TECHNICAL DATA SHEET
NSN 5945-01-132-6093Government record, cited

Relay, Electromagnetic5945-01-132-6093

NSN 5945-01-132-6093 · NIIN 011326093 · Part number 1730-057
Woodward, Inc. · FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components · CAGE 31361
Government record, cited
NSN 5945-01-132-6093 — this item is cataloged by the U.S. Government under National Stock Number 5945-01-132-6093. Manufacturer of record part number: 1730-057.
Also searched as  5945-01-132-6093 · 5945011326093 · NIIN 011326093 · 01-132-6093 · FSC 5945 Relays and Solenoids · CAGE 31361 · 1730-057
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 230.0 AC AND 30.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 1.0 AMPERES AC INDUCTIVE LOAD
  • Main Contact Load Current Rating at Maximum Rated Voltage: 0.1 MILLIAMPERES AC LAMP LOAD
Identification
  • NSN: 5945-01-132-6093
  • NIIN: 011326093
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1730-057
  • Manufacturer: Woodward, Inc.
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-132-6093, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Woodward, Inc.. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-132-6093
Primary Part Number1730-057
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
ManufacturerWoodward, Inc.
StatusACTIVE
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts230.0 AC AND 30.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Center to Center Distance Between Mounting Facilities Parallel to Length1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage1.0 AMPERES AC INDUCTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage0.1 MILLIAMPERES AC LAMP LOAD
Main Contact Load Current Rating at Maximum Rated Voltage0.5 MILLIAMPERES AC MOTOR LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Frequency in Hertz60.0 NOMINAL AND 400.0 NOMINAL
Winding DC Resistance Rating330.0 OHMS NOMINAL SINGLE WINDING
Time Delay0.004 SECONDS NOMINAL FIXED RELEASE TIME
Time Delay0.011 SECONDS NOMINAL FIXED OPERATE TIME
Coil Quantity1
Environmental ProtectionHERMETIC
Cubic Measure1.789 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Terminal Type and Quantity8 WIRE HOOK ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
1730-057 PRIMARY Woodward, Inc. (USA)
Reference documents
ReferenceMeaning
1730-057 5/9 Secondary reference
Woodward, Inc. Div Fuel Systems and Controls
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-132-6093?

NSN 5945-01-132-6093 is a Relay,electromagnetic, manufactured by Woodward, Inc., classified under FSC 5945, Relays and Solenoids. Status: active.

What part numbers are listed for NSN 5945-01-132-6093?

NSN 5945-01-132-6093 has 1 manufacturer part number on file: 1730-057 (Woodward, Inc.).

What are the specifications of 1730-057?

Key specifications for 1730-057: Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 1.234 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 230.0 AC AND 30.0 DC; Fragility Factor: MODERATELY RUGGED. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-132-6093 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com