PartsTable TECHNICAL DATA SHEET
NSN 5945-01-062-0166Government record, cited

Relay, Electromagnetic5945-01-062-0166

NSN 5945-01-062-0166 · NIIN 010620166
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-062-0166 · 5945010620166 · NIIN 010620166 · 01-062-0166 · FSC 5945 Relays and Solenoids · 68F1-12DC-SC0 · 388X-2
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 1 THREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Arc Quenching Method: AIR
  • Precious Material: SILVER
  • Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
  • Thread Length: 0.312 INCHES MINIMUM SINGLE MOUNTING FACILITY IN
Identification
  • NSN: 5945-01-062-0166
  • NIIN: 010620166
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-062-0166, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-062-0166
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity1 THREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts240.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Arc Quenching MethodAIR
Precious MaterialSILVER
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
Thread Length0.312 INCHES MINIMUM SINGLE MOUNTING FACILITY IN
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Winding DC Resistance Rating120.0 OHMS NOMINAL SINGLE WINDING
Thread DirectionRIGHT-HAND SINGLE MOUNTING FACILITY
Nominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY IN
Time Delay0.03 SECONDS MAXIMUM FIXED OPERATE TIME
Time Delay0.022 SECONDS MAXIMUM FIXED RELEASE TIME
Coil Quantity1
Surface TreatmentCADMIUM CONTACT
Precious Material and LocationCONTACTS SILVER
Cubic Measure3.996 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Thread Class2B SINGLE MOUNTING FACILITY
Thread Quantity Per Inch32 SINGLE MOUNTING FACILITY
MaterialSILVER CONTACT
Energizing Element Power Rating1.2 WATTS
Terminal Type and Quantity5 TAB, SOLDER LUG ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
68F1-12DC-SC0 5/9 Secondary reference
Sigma Instruments Inc
388X-2 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-062-0166?

NSN 5945-01-062-0166 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-062-0166?

Key specifications for 5945-01-062-0166: Mounting Facility Type and Quantity: 1 THREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 1.281 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 240.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-062-0166 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com