PartsTable TECHNICAL DATA SHEET
NSN 5945-01-033-9341Government record, cited

Relay, Electromagnetic5945-01-033-9341

NSN 5945-01-033-9341 · NIIN 010339341
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-01-033-9341 · 5945010339341 · NIIN 010339341 · 01-033-9341 · FSC 5945 Relays and Solenoids · 213ACPSRX17 · 3722B12B · 211ACPSRX-46 · W213ACPSRX-4 · 802290-2
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 120.0 AC AND 28.0 DC
  • Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Time Delay: 1.00 SECONDS MINIMUM AND 10.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
  • Coil Quantity: 1
  • Environmental Protection: DUSTPROOF
Identification
  • NSN: 5945-01-033-9341
  • NIIN: 010339341
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-01-033-9341, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 11 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-01-033-9341
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts120.0 AC AND 28.0 DC
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Time Delay1.00 SECONDS MINIMUM AND 10.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
Coil Quantity1
Environmental ProtectionDUSTPROOF
Winding Quantity1
Terminal Type and Quantity6 PIN CONTACTS
Terminal Type and Quantity2 PIN ENERGIZING ELEMENT
Nonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
213ACPSRX17 5/9 Secondary reference
U.S. Government activity
3722B12B C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
211ACPSRX-46 3/2 Design control — primary reference
U.S. Government activity
W213ACPSRX-4 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
802290-2 5/2 Secondary reference
U.S. Government activity
6X153 C/1 Advisory reference — outside the item-of-supply concept
W.w. Grainger, Inc. Div Government Sales Division
SSC22ABA 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-01-033-9341?

NSN 5945-01-033-9341 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-01-033-9341?

Key specifications for 5945-01-033-9341: Mounting Facility Type and Quantity: 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY; Overall Height: 1.750 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 120.0 AC AND 28.0 DC; Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD. 11 specifications are documented in the U.S. Government catalog.

Is NSN 5945-01-033-9341 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com