The Relay,electromagnetic, cataloged under National Stock Number 5945-01-026-8303, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-01-026-8303 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Nonpile-Up Auxiliary Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 115.0 AC AND 28.0 DC |
| Mounting Facility Pattern | RECTANGULAR SINGLE MOUNTING FACILITY |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Main Contact Load Current Rating at Maximum Rated Voltage | 50.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Unthreaded Mounting Hole Diameter | 0.170 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Winding DC Resistance Rating | 200.0 OHMS NOMINAL SINGLE WINDING |
| Auxiliary Contact Load Current Rating at Maximum Rated Voltage | 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
| Specification/standard Data | 96906-MS27751 GOVERNMENT STANDARD |
| Time Delay | 0.05 SECONDS MAXIMUM FIXED OPERATE TIME |
| Time Delay | 0.025 SECONDS MAXIMUM FIXED RELEASE TIME |
| Coil Quantity | 1 |
| Environmental Protection | HERMETIC |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Test Data Document | 81349-MILR6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Terminal Type and Quantity | 12 THREADED STUD ALL FUNCTIONS |
| Nonpile-Up Main Contact Arrangement | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| Auxiliary Contact Maximum Voltage Rating in Volts | 115.0 AC AND 28.0 DC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 5945PL1667633 | 6/9 Informative reference only Jednolity Indeks Materialowy - Uniform Material Index |
| MS27751-5 | 2/2 Government specification standardization U.S. Government activity |
| MIL-R-6106 | 5/9 Secondary reference U.S. Government activity |
| HA3A002 | C/1 Advisory reference — outside the item-of-supply concept Leach International Corp Div Leach International Corporation |
| MIL-PRF-6106 | 4/1 Identification reference U.S. Government activity |
| 1604273-5 | C/1 Advisory reference — outside the item-of-supply concept Lockheed Martin Corporation Div Rms - Mitchel Field |
| 10193526 | 6/9 Informative reference only Nimikkeistokeskus Ncb Finland |
NSN 5945-01-026-8303 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-01-026-8303: Nonpile-Up Auxiliary Contact Arrangement: 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 3.130 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC. 22 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.