The Relay,reed, cataloged under National Stock Number 5945-01-013-5214, is classified within Federal Supply Class 5945 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M. Government technical data includes 13 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-01-013-5214 |
| Primary Part Number | MIL-DTL-5757/29 |
| Item Name | Relay,reed |
| FSC / FSG | 5945 / 59 — No Item Name Available |
| Manufacturer | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| Status | ACTIVE |
| Nonpile-Up Main Contact Arrangement | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| Main Contact Load Current Rating at Maximum Rated Voltage | 500.0 MILLIAMPERES DC RESISTIVE LOAD |
| Specification/standard Data | 81349--575/29 GOVERNMENT SPECIFICATION |
| Main Contact Maximum Voltage Rating in Volts | 28.0 DC |
| Mounting Facility Type and Quantity | 1 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| Terminal Type and Quantity | 6 PIN ALL FUNCTIONS |
| Test Data Document | 81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Operating Voltage Rating and Type at Specified Temp | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Duty Type | CONTINUOUS |
| Coil Quantity | 11 |
| Winding DC Resistance Rating | 925.0 OHMS NOMINAL SINGLE WINDING |
| Winding Quantity | 11 |
| Environmental Protection | HERMETICHERMETIC |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| MIL-DTL-5757/29 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| M5757/29-003 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| MIL-R-5757/29 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| 194HE2A-22003 | Sigma Instruments Inc (USA) |
NSN 5945-01-013-5214 is a Relay,reed, manufactured by Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M, classified under FSC 5945 (No Item Name Available). Status: active.
NSN 5945-01-013-5214 has 4 cross-referenced part numbers: MIL-DTL-5757/29 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), M5757/29-003 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), MIL-R-5757/29 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), 194HE2A-22003 (Sigma Instruments Inc).
There are 12 known substitutes for 5945-01-013-5214: 5945-00-025-7232, 5945-00-088-5425, 5945-00-088-5426 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for MIL-DTL-5757/29: Overall Width: 0.700 INCHES NOMINAL0.700 INCHES NOMINAL IN; Nonpile-Up Main Contact Arrangement: 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION; Main Contact Load Current Rating at Maximum Rated Voltage: 500.0 MILLIAMPERES DC RESISTIVE LOAD; Specification/standard Data: 81349--575/29 GOVERNMENT SPECIFICATION. 16 total characteristics are documented in the Federal Logistics Information System.