The Relay,electromagnetic, cataloged under National Stock Number 5945-00-949-5145, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-949-5145 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 9 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 120.0 DC |
| Overall Diameter | 1.312 INCHES MAXIMUM IN |
| Precious Material | PLATINUM |
| Duty Type | CONTINUOUS |
| Winding DC Resistance Rating | 160.0 OHMS NOMINAL ALL WINDINGS |
| Features Provided | LATCHING CONTACTS AND POLARIZED |
| Nominal Operating Current Rating and Type | 1.4 MILLIAMPERES DC ALL WINDINGS |
| Coil Quantity | 2 |
| Environmental Protection | SHOCK RESISTANT AND VIBRATION RESISTANT |
| Precious Material and Location | CONTACTS PLATINUM |
| Winding Quantity | 2 |
| Material | PLATINUM AND NICKEL CONTACT |
| Terminal Type and Quantity | 1 STANDARD TUBE BASE ALL FUNCTIONS |
| Nonpile-Up Main Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 0N008343 | 7/2 Vendor item drawing reference U.S. Government activity |
| 72A03Z-95738 | 3/9 Design control — primary reference Sigma Instruments Inc |
NSN 5945-00-949-5145 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-949-5145: Mounting Facility Type and Quantity: 9 PLUG-IN TERMINAL(S) SINGLE MOUNTING FACILITY; Main Contact Maximum Voltage Rating in Volts: 120.0 DC; Overall Diameter: 1.312 INCHES MAXIMUM IN; Precious Material: PLATINUM. 15 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.