The Relay,electromagnetic, cataloged under National Stock Number 5945-00-939-5842, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-939-5842 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| Pile-Up Main Contact Form Arrangement | 3A3A1B1C |
| Main Contact Maximum Voltage Rating in Volts | 250.0 AC AND 28.0 DC |
| Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
| Arc Quenching Method | CAPACITOR |
| Main Contact Load Current Rating at Maximum Rated Voltage | 75.0 AMPERES AC AND 75.0 AMPERES DC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle | 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Winding DC Resistance Rating | 568.0 OHMS NOMINAL SINGLE WINDING |
| Nominal Operating Current Rating and Type | 4.8 AMPERES DC SINGLE WINDING |
| Coil Quantity | 1 |
| Environmental Protection | WATER RESISTANT |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Terminal Type and Quantity | 19 PIN ALL FUNCTIONS |
| Mounting Slot Width | 0.203 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 401-1608-00 | 5/2 Secondary reference U.S. Government activity |
| XB1861 | 5/9 Secondary reference Telemecanique Inc |
| B730JAX1861 | 5/9 Secondary reference Telemecanique Inc |
| 401-1608-000 | 5/2 Secondary reference U.S. Government activity |
| 401-1608-00 | 3/9 Design control — primary reference Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
NSN 5945-00-939-5842 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-939-5842: Mounting Facility Type and Quantity: 3 SLOTTED HOLE SINGLE MOUNTING FACILITY; Overall Height: 4.120 INCHES NOMINAL IN; Pile-Up Main Contact Form Arrangement: 3A3A1B1C; Main Contact Maximum Voltage Rating in Volts: 250.0 AC AND 28.0 DC. 16 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.