The Solenoid,electrical, cataloged under National Stock Number 5945-00-852-0659, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-852-0659 |
| Item Name | Solenoid,electrical |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Body Diameter | 1.609 INCHES NOMINAL IN |
| Mounting Facility Type and Quantity | 2 THREADED STUD(S) |
| Actuator Diameter | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM IN |
| Inclosure Type | FULLY INCLOSED |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | BASE END ACTUATOR |
| Mounting Facility Pattern | TWO POSITION IN-LINE |
| Rotation Direction and Energizing Stroke in Angular Deg | 60.0 CLOCKWISE |
| Power Takeoff Connection Hole Diameter | 0.078 INCHES NOMINAL IN |
| Body Height | 1.000 INCHES NOMINAL IN |
| Duty Type | CONTINUOUS |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Power Takeoff Connection Type | HOLLOW-DRILLED |
| Magnetic Coil Quantity | 1 |
| Terminal Location | TOP EDGE |
| Nominal Thread Size | 0.138 INCHES MOUNTING FACILITY STUD IN |
| Actuator Length | 0.493 INCHES MINIMUM AND 0.513 INCHES MAXIMUM IN |
| Actuator Stroke Type | ROTARY |
| Environmental Protection | DUSTPROOF |
| Cubic Measure | 2.032 CUBIC INCHES |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.052 INCHES MINIMUM AND 1.072 INCHES MAXIMUM IN |
| Thread Class | 2A MOUNTING FACILITY STUD A |
| Thread Quantity Per Inch | 32 MOUNTING FACILITY STUD |
| Material | STEEL CASE |
| Terminal Type and Quantity | 2 WIRE LEAD |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) MOUNTING FACILITY STUD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 018-033 | 3/9 Design control — primary reference Eastman Kodak Co |
| 2-018A033 | 5/9 Secondary reference Eastman Kodak Co Commercial & Government Systems |
NSN 5945-00-852-0659 is a Solenoid,electrical, classified under FSC 5945, Relays and Solenoids. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 2910-01-169-7359. Verify interchangeability with system specifications before substitution.
Key specifications for 5945-00-852-0659: Body Diameter: 1.609 INCHES NOMINAL IN; Mounting Facility Type and Quantity: 2 THREADED STUD(S); Actuator Diameter: 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM IN; Inclosure Type: FULLY INCLOSED. 26 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.