PartsTable TECHNICAL DATA SHEET
NSN 5945-00-805-0780Government record, cited

Relay, Thermal5945-00-805-0780

NSN 5945-00-805-0780 · NIIN 008050780
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-805-0780 · 5945008050780 · NIIN 008050780 · 00-805-0780 · FSC 5945 Relays and Solenoids · HM01N028 · HM01N028V0-5SEC · 740105
Nearby stock numbers  ·
Features
  • Relay,thermal — FSC 5945
  • Mounting Facility Type and Quantity: 1 PLUG-IN
  • Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Delay Time in Seconds: 0.5 FIXED OPERATE NOMINAL
  • Contact Arrangement: SINGLE POLE, SINGLE THROW, NORMALLY OPEN
  • Overall Diameter: 0.797 INCHES NOMINAL IN
  • Heater Voltage Rating in Volts: 28.0
  • Contact Maximum Current Rating in Amps: 3.0 AC OR 1.0 DC
Identification
  • NSN: 5945-00-805-0780
  • NIIN: 008050780
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,thermal, cataloged under National Stock Number 5945-00-805-0780, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 9 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-805-0780
Item NameRelay,thermal
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity1 PLUG-IN
Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Delay Time in Seconds0.5 FIXED OPERATE NOMINAL
Contact ArrangementSINGLE POLE, SINGLE THROW, NORMALLY OPEN
Overall Diameter0.797 INCHES NOMINAL IN
Heater Voltage Rating in Volts28.0
Contact Maximum Current Rating in Amps3.0 AC OR 1.0 DC
Environmental ProtectionHERMETIC
Terminal Type and Quantity7 PIN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5945-00-849-8750271-1216P1 POSSIBLE MATCH
RELAY,THERMAL
Possible match (shared part number)Raytheon Company Dba Raytheon Co
2915-00-960-9433740105 POSSIBLE MATCH
BODY,LOWER
Possible match (shared part number)Transdigm Inc Div Aero Fluid Products
1680-01-483-485374010-5 POSSIBLE MATCH
TRACK,AIRCRAFT SEAT
Possible match (shared part number)B/e Aerospace Inc Dba Interturbine
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
HM01N028 5/1 Secondary reference
U.S. Government activity
HM01N028V0-5SEC 5/2 Secondary reference
U.S. Government activity
740105 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5945-00-849-8750POSSIBLE MATCH
RELAY,THERMAL
271-1216P1
2915-00-960-9433POSSIBLE MATCH
BODY,LOWER
740105
1680-01-483-4853POSSIBLE MATCH
TRACK,AIRCRAFT SEAT
74010-5

Frequently Asked Questions

What is NSN 5945-00-805-0780?

NSN 5945-00-805-0780 is a Relay,thermal, classified under FSC 5945, Relays and Solenoids. Status: active.

What NSN replaces 5945-00-805-0780?

3 possible matches (shared part number, not a government interchangeability claim): 5945-00-849-8750, 2915-00-960-9433, 1680-01-483-4853. Verify interchangeability with system specifications before substitution.

What are the specifications of 5945-00-805-0780?

Key specifications for 5945-00-805-0780: Mounting Facility Type and Quantity: 1 PLUG-IN; Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Delay Time in Seconds: 0.5 FIXED OPERATE NOMINAL; Contact Arrangement: SINGLE POLE, SINGLE THROW, NORMALLY OPEN. 9 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-805-0780 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com