PartsTable TECHNICAL DATA SHEET
NSN 5945-00-754-7276Government record, cited

Relay, Electromagnetic5945-00-754-7276

NSN 5945-00-754-7276 · NIIN 007547276
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-754-7276 · 5945007547276 · NIIN 007547276 · 00-754-7276 · FSC 5945 Relays and Solenoids · 5945007547276 · MIL-PRF-6106 · MIL-R-6106 · MS24141-D1 · 6042H159
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC
  • Fragility Factor: MODERATELY RUGGED
  • Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY
  • Arc Quenching Method: AIR
  • Main Contact Load Current Rating at Maximum Rated Voltage: 100.0 AMPERES AC AND 100.0 AMPERES DC RESISTIVE LOAD
  • Main Contact Load Current Rating at Maximum Rated Voltage: 100.0 AMPERES DC INDUCTIVE LOAD
Identification
  • NSN: 5945-00-754-7276
  • NIIN: 007547276
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-00-754-7276, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-754-7276
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts115.0 AC AND 28.0 DC
Fragility FactorMODERATELY RUGGED
Mounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
Arc Quenching MethodAIR
Main Contact Load Current Rating at Maximum Rated Voltage100.0 AMPERES AC AND 100.0 AMPERES DC RESISTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage100.0 AMPERES DC INDUCTIVE LOAD
Main Contact Load Current Rating at Maximum Rated Voltage50.0 AMPERES AC AND 50.0 AMPERES DC LAMP LOAD
Main Contact Load Current Rating at Maximum Rated Voltage75.0 AMPERES AC AND 100.0 AMPERES DC MOTOR LOAD
Duty TypeCONTINUOUS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating64.5 OHMS NOMINAL SINGLE WINDING
Specification/standard Data96906-MS24141 GOVERNMENT STANDARD
Time Delay0.02 SECONDS MAXIMUM FIXED OPERATE TIME
Time Delay0.01 SECONDS MAXIMUM FIXED RELEASE TIME
Coil Quantity1
Environmental ProtectionHERMETIC
Cubic Measure34.602 CUBIC INCHES
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Center to Center Distance Between Mounting Facilities Parallel to Width2.615 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Test Data Document81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Terminal Type and Quantity4 THREADED STUD ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
Purpose for Which DesignedGENERAL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
5945007547276 5/9 Secondary reference
E.c.a Etablissement Centrald'approvisionnement Des Forces Armee
MIL-PRF-6106 4/1 Identification reference
U.S. Government activity
MIL-R-6106 5/9 Secondary reference
U.S. Government activity
MS24141-D1 2/2 Government specification standardization
U.S. Government activity
6042H159 C/1 Advisory reference — outside the item-of-supply concept
Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc
6042H159 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-00-754-7276?

NSN 5945-00-754-7276 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-00-754-7276?

Key specifications for 5945-00-754-7276: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 3.250 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-754-7276 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.