The Relay,thermal, cataloged under National Stock Number 5945-00-696-4862, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-696-4862 |
| Primary Part Number | 403-0006-00 |
| Item Name | Relay,thermal |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Manufacturer | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 403-0006-00 PRIMARY | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems (USA) |
| Reference | Meaning |
|---|---|
| 403-0006-000 | 5/2 Secondary reference U.S. Government activity |
NSN 5945-00-696-4862 is a Relay,thermal, manufactured by Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems, classified under FSC 5945, Relays and Solenoids. Status: active.
NSN 5945-00-696-4862 has 1 manufacturer part number on file: 403-0006-00 (Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems).
Key specifications for 403-0006-00: Special Features: CONTACT DATA,SPST,NORMALLY CLOSEDREF DWG GROUP 217,ELECTRICAL RATINGS,DC,28V MAX,0.5 AMP NOM CURRENT RATING;HEATER DATA,DC,7.5 V RATING,NOT RATED FOR W,0.300 AMP CURRENT RATING,DC,36 V RATING,NOT RATED FOR W,0.090 AMP CURRENT RATING;TERMINAL DATA,3 HEATER TERMINALS,2 TERMINALS FOR CONTACTS;HERMETICALLY SEALEDMETAL ENCLOSURE;AMBIENT TEMP RANGE COMPENSATED FOR OPERATION FROM MINUS 55 DEG C TO PLUS 85 DEG C;RATED FOR ACTUATION TIME,4 TO 11 SEC OPERATING TIME,OPERATING TIME IS ADJUSTABLE;O/A DIM.,EXCL TERMINALS,2.625 IN. LG,0.750 IN. DIA;CLAMP MTD;SPECIAL FEATURES,TERMINALS NOS 4,6,7 ARE CONECTED TO NO. 1 TERMINAL;P/O,JETDS,RADIO SET,TYPE NO. AN/GRC-19 V. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.