PartsTable TECHNICAL DATA SHEET
NSN 5945-00-685-9334Government record, cited

Relay, Electromagnetic5945-00-685-9334

NSN 5945-00-685-9334 · NIIN 006859334
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-685-9334 · 5945006859334 · NIIN 006859334 · 00-685-9334 · FSC 5945 Relays and Solenoids · 585891 · SMC142877 · 604215-000 · 604215-000
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S) SINGLE MOUNTING FACILITY
  • FSC Application Data: RELAY,ARMATURE,EXCEPT ENGINE
  • Pile-Up Main Contact Form Arrangement: 3A A
  • Main Contact Maximum Voltage Rating in Volts: 50.0 DC
  • Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 500.0 MILLIAMPERES DC RESISTIVE LOAD
Identification
  • NSN: 5945-00-685-9334
  • NIIN: 006859334
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-00-685-9334, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-685-9334
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity2 THREADED HOLE(S) SINGLE MOUNTING FACILITY
FSC Application DataRELAY,ARMATURE,EXCEPT ENGINE
Pile-Up Main Contact Form Arrangement3A A
Main Contact Maximum Voltage Rating in Volts50.0 DC
Mounting Facility PatternIN-LINE SINGLE MOUNTING FACILITY
Center to Center Distance Between Mounting Facilities Parallel to Length0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage500.0 MILLIAMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Winding DC Resistance Rating560.0 OHMS NOMINAL SINGLE WINDING
Nominal Operating Current Rating and Type10.0 MILLIAMPERES DC SINGLE WINDING
Nominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY IN
Coil Quantity1
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Thread Class2B SINGLE MOUNTING FACILITY
Thread Quantity Per Inch32 SINGLE MOUNTING FACILITY
Terminal Type and Quantity8 PIN ALL FUNCTIONS
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
585891 5/9 Secondary reference
Itt Telecom Products Corp Network Systems Div
SMC142877 3/2 Design control — primary reference
U.S. Government activity
604215-000 5/9 Secondary reference
Xy Resources, Inc. Dba Xy Resources, Inc.
604215-000 5/9 Secondary reference
Stromberg-Carlson Corp a Plessey Telecommunications Co

Frequently Asked Questions

What is NSN 5945-00-685-9334?

NSN 5945-00-685-9334 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-00-685-9334?

Key specifications for 5945-00-685-9334: Mounting Facility Type and Quantity: 2 THREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 1.790 INCHES NOMINAL IN; FSC Application Data: RELAY,ARMATURE,EXCEPT ENGINE; Pile-Up Main Contact Form Arrangement: 3A A. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-685-9334 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com