PartsTable TECHNICAL DATA SHEET
NSN 5945-00-474-5402Government record, cited

Relay, Electromagnetic5945-00-474-5402

NSN 5945-00-474-5402 · NIIN 004745402
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-474-5402 · 5945004745402 · NIIN 004745402 · 00-474-5402 · FSC 5945 Relays and Solenoids · 827474 · 4750A21HE0 · 0C2F115VAC3-15AMPDC
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Main Contact Maximum Voltage Rating in Volts: 230.0 AC
  • Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY
  • Arc Quenching Method: CAPACITOR
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Main Contact Load Current Rating at Maximum Rated Voltage: 11.0 AMPERES AC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
Identification
  • NSN: 5945-00-474-5402
  • NIIN: 004745402
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-00-474-5402, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-474-5402
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Main Contact Maximum Voltage Rating in Volts230.0 AC
Mounting Facility PatternRECTANGULAR SINGLE MOUNTING FACILITY
Arc Quenching MethodCAPACITOR
Center to Center Distance Between Mounting Facilities Parallel to Length4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Main Contact Load Current Rating at Maximum Rated Voltage11.0 AMPERES AC RESISTIVE LOAD
Duty TypeCONTINUOUS
Unthreaded Mounting Hole Diameter0.199 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Frequency in Hertz60.0 NOMINAL
Nominal Operating Current Rating and Type11.0 AMPERES AC ALL WINDINGS
Coil Quantity2
Environmental ProtectionCORROSION RESISTANT AND WATERTIGHT
Winding Quantity2
Operating Voltage Rating and Type at Specified Temp115.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS
Center to Center Distance Between Mounting Facilities Parallel to Width1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Terminal Type and Quantity5 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
2530-01-657-5825827474 POSSIBLE MATCH
PARTS KIT,DISK BRAKE
Possible match (shared part number)Nexen Group Inc.
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
827474 3/9 Design control — primary reference
L3 Aviation Products, Inc. Dba L3 Technologies
4750A21HE0 5/9 Secondary reference
Jennings Technology Company Llc Dba Jennings
0C2F115VAC3-15AMPDC 5/9 Secondary reference
Jennings Technology Company Llc Dba Jennings
Related Parts
2530-01-657-5825POSSIBLE MATCH
PARTS KIT,DISK BRAKE
827474

Frequently Asked Questions

What is NSN 5945-00-474-5402?

NSN 5945-00-474-5402 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What NSN replaces 5945-00-474-5402?

1 possible match (shared part number, not a government interchangeability claim): 2530-01-657-5825. Verify interchangeability with system specifications before substitution.

What are the specifications of 5945-00-474-5402?

Key specifications for 5945-00-474-5402: Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 7.375 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 230.0 AC; Mounting Facility Pattern: RECTANGULAR SINGLE MOUNTING FACILITY. 17 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-474-5402 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com