The Relay,electromagnetic, cataloged under National Stock Number 5945-00-401-0115, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-401-0115 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 3 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 115.0 AC AND 28.0 DC |
| Fragility Factor | MODERATELY RUGGED |
| Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
| Arc Quenching Method | AIR |
| Main Contact Load Current Rating at Maximum Rated Voltage | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle | 0.300 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Winding DC Resistance Rating | 500.0 OHMS NOMINAL SINGLE WINDING |
| Nominal Operating Current Rating and Type | 27.0 MILLIAMPERES DC SINGLE WINDING |
| Nominal Thread Size | 0.112 INCHES SINGLE MOUNTING FACILITY IN |
| Coil Quantity | 1 |
| Environmental Protection | HERMETIC |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 13.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 0.700 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Thread Class | 2A SINGLE MOUNTING FACILITY A |
| Terminal Type and Quantity | 14 PIN ALL FUNCTIONS |
| Nonpile-Up Main Contact Arrangement | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| Purpose for Which Designed | GENERAL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 3SAH5112K1 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| 3SAH5112K1 | C/1 Advisory reference — outside the item-of-supply concept General Electric Co Armament and Electrical Systems Dept Electrical Systems Products Dept |
| 3SAH5112K1 | 5/9 Secondary reference Genicom Corp |
| 3SAH5112K1 | 3/9 Design control — primary reference Communications Instruments Inc Div of Cii Technologies |
NSN 5945-00-401-0115 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-401-0115: Mounting Facility Type and Quantity: 3 THREADED STUD(S) SINGLE MOUNTING FACILITY; Overall Height: 0.610 INCHES NOMINAL IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC; Fragility Factor: MODERATELY RUGGED. 22 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.