The Relay,electromagnetic, cataloged under National Stock Number 5945-00-295-6419, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-295-6419 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) SECOND MOUNTING FACILITY |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) FIRST MOUNTING FACILITY |
| Pile-Up Main Contact Form Arrangement | 2C AND 2C |
| Main Contact Maximum Voltage Rating in Volts | 115.0 AC AND 24.0 DC |
| Mounting Facility Pattern | RECTANGULAR FIRST MOUNTING FACILITY |
| Mounting Facility Pattern | RECTANGULAR SECOND MOUNTING FACILITY |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 0.844 INCHES NOMINAL FIRST MOUNTING FACILITY IN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.062 INCHES NOMINAL SECOND MOUNTING FACILITY IN |
| Main Contact Load Current Rating at Maximum Rated Voltage | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Winding DC Resistance Rating | 300.0 OHMS NOMINAL SINGLE WINDING |
| Nominal Thread Size | 0.112 INCHES FIRST MOUNTING FACILITY IN |
| Nominal Thread Size | 0.112 INCHES SECOND MOUNTING FACILITY IN |
| Coil Quantity | 1 |
| Environmental Protection | HUMIDITY RESISTANT AND SALT WATER RESISTANT |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 0.531 INCHES NOMINAL FIRST MOUNTING FACILITY IN |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 0.844 INCHES NOMINAL SECOND MOUNTING FACILITY IN |
| Thread Class | 2B SECOND MOUNTING FACILITY |
| Thread Class | 2B FIRST MOUNTING FACILITY |
| Terminal Type and Quantity | 14 PIN ALL FUNCTIONS |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SECOND MOUNTING FACILITY |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) FIRST MOUNTING FACILITY |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| PKX1 | 3/9 Design control — primary reference Allied Controls, Inc. |
NSN 5945-00-295-6419 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-295-6419: Mounting Facility Type and Quantity: 4 THREADED HOLE(S) SECOND MOUNTING FACILITY; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) FIRST MOUNTING FACILITY; Overall Height: 2.120 INCHES NOMINAL IN; Pile-Up Main Contact Form Arrangement: 2C AND 2C. 24 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.