The Relay,electromagnetic, cataloged under National Stock Number 5945-00-259-2118, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-259-2118 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 2 THREADED STUD(S) SINGLE MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 110.0 AC |
| Mounting Facility Pattern | IN-LINE SINGLE MOUNTING FACILITY |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY IN |
| Main Contact Load Current Rating at Maximum Rated Voltage | 3.0 AMPERES AC RESISTIVE LOAD |
| Duty Type | CONTINUOUS |
| Winding DC Resistance Rating | 14.4 KILOHMS MINIMUM AND 17.6 KILOHMS MAXIMUM SINGLE WINDING |
| Nominal Operating Current Rating and Type | 1.7 MILLIAMPERES DC SINGLE WINDING |
| Nominal Thread Size | 0.138 INCHES SINGLE MOUNTING FACILITY IN |
| Coil Quantity | 1 |
| Environmental Protection | HERMETIC |
| Winding Quantity | 1 |
| Operating Voltage Rating and Type at Specified Temp | 26.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| Thread Class | 2A SINGLE MOUNTING FACILITY A |
| Thread Quantity Per Inch | 32 SINGLE MOUNTING FACILITY |
| Terminal Type and Quantity | 5 PIN ALL FUNCTIONS |
| Nonpile-Up Main Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |
| Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY SIGMA SPEC N0. 90133 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 5RJ90133 | 3/9 Design control — primary reference Sigma Instruments Inc |
NSN 5945-00-259-2118 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-259-2118: Mounting Facility Type and Quantity: 2 THREADED STUD(S) SINGLE MOUNTING FACILITY; Overall Height: 1.500 INCHES MINIMUM AND 1.563 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 110.0 AC; Mounting Facility Pattern: IN-LINE SINGLE MOUNTING FACILITY. 19 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.