The Relay,electromagnetic, cataloged under National Stock Number 5945-00-241-9632, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5945-00-241-9632 |
| Item Name | Relay,electromagnetic |
| FSC / FSG | 5945 / 59 — Relays and Solenoids |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 3 UNTHREADED HOLE(S) FIRST MOUNTING FACILITY |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) SECOND MOUNTING FACILITY |
| Main Contact Maximum Voltage Rating in Volts | 115.0 AC AND 28.0 DC |
| Fragility Factor | MODERATELY RUGGED |
| Mounting Facility Pattern | IN-LINE SECOND MOUNTING FACILITY |
| Mounting Facility Pattern | IN-LINE FIRST MOUNTING FACILITY |
| Arc Quenching Method | AIR |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.187 INCHES MINIMUM AND 2.374 INCHES MAXIMUM FIRST MOUNTING FACILITY IN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.700 INCHES NOMINAL SECOND MOUNTING FACILITY IN |
| Main Contact Load Current Rating at Maximum Rated Voltage | 5.0 AMPERES AC AND 5.0 AMPERES DC LAMP LOAD |
| Main Contact Load Current Rating at Maximum Rated Voltage | 20.0 AMPERES AC AND 20.0 AMPERES DC RESISTIVE LOAD |
| Main Contact Load Current Rating at Maximum Rated Voltage | 20.0 AMPERES AC AND 20.0 AMPERES DC MOTOR LOAD |
| Main Contact Load Current Rating at Maximum Rated Voltage | 20.0 AMPERES AC AND 15.0 AMPERES DC INDUCTIVE LOAD |
| Duty Type | CONTINUOUS |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY IN |
| Unthreaded Mounting Hole Diameter | 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY IN |
| Features Provided | LATCHING CONTACTS AND POLARIZED |
| Nominal Operating Current Rating and Type | 250.0 MILLIAMPERES DC ALL WINDINGS |
| Specification/standard Data | 96906-MS27706 GOVERNMENT STANDARD |
| Time Delay | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| Time Delay | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
| Coil Quantity | 2 |
| Environmental Protection | HERMETIC |
| Cubic Measure | 35.241 CUBIC INCHES |
| Winding Quantity | 2 |
| Operating Voltage Rating and Type at Specified Temp | 25.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 9325-8398 | C/1 Advisory reference — outside the item-of-supply concept Leach International Corp Div Leach International Corporation |
| MIL-PRF-6106 | 4/1 Identification reference U.S. Government activity |
| MIL-R-6106 | 5/9 Secondary reference U.S. Government activity |
| MS27706-1B | 2/2 Government specification standardization U.S. Government activity |
NSN 5945-00-241-9632 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.
Key specifications for 5945-00-241-9632: Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S) FIRST MOUNTING FACILITY; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) SECOND MOUNTING FACILITY; Overall Height: 3.200 INCHES MAXIMUM IN; Main Contact Maximum Voltage Rating in Volts: 115.0 AC AND 28.0 DC. 27 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.