PartsTable TECHNICAL DATA SHEET
NSN 5945-00-084-3427Government record, cited

Relay, Electromagnetic5945-00-084-3427

NSN 5945-00-084-3427 · NIIN 000843427
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-084-3427 · 5945000843427 · NIIN 000843427 · 00-084-3427 · FSC 5945 Relays and Solenoids · 94-4134 · 974-0727-00
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 3 THREADED STUD(S) SINGLE MOUNTING FACILITY
  • Pile-Up Main Contact Form Arrangement: 1D1B
  • Main Contact Maximum Voltage Rating in Volts: 28.0 DC
  • Mounting Facility Pattern: TRIANGLE SINGLE MOUNTING FACILITY
  • Main Contact Load Current Rating at Maximum Rated Voltage: 500.0 MILLIAMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle: 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Identification
  • NSN: 5945-00-084-3427
  • NIIN: 000843427
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-00-084-3427, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-084-3427
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity3 THREADED STUD(S) SINGLE MOUNTING FACILITY
Pile-Up Main Contact Form Arrangement1D1B
Main Contact Maximum Voltage Rating in Volts28.0 DC
Mounting Facility PatternTRIANGLE SINGLE MOUNTING FACILITY
Main Contact Load Current Rating at Maximum Rated Voltage500.0 MILLIAMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating300.0 OHMS NOMINAL SINGLE WINDING
Nominal Operating Current Rating and Type90.0 MILLIAMPERES DC ALL WINDINGS
Nominal Thread Size0.138 INCHES SINGLE MOUNTING FACILITY IN
Time Delay0.002 SECONDS NOMINAL FIXED RELEASE TIME
Time Delay0.0014 SECONDS NOMINAL FIXED OPERATE TIME
Coil Quantity1
Environmental ProtectionHERMETIC
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp27.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Thread Class2A SINGLE MOUNTING FACILITY A
Thread Quantity Per Inch32 SINGLE MOUNTING FACILITY
Terminal Type and Quantity8 PIN ALL FUNCTIONS
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
2540-01-355-8942944134 POSSIBLE MATCH
CONTROL BOX,ELECTRICAL,VEHICULAR
Possible match (shared part number)Austin-Westran Llc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
94-4134 5/9 Secondary reference
Midland-Ross Corp Midtex Div
974-0727-00 3/9 Design control — primary reference
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
Related Parts
2540-01-355-8942POSSIBLE MATCH
CONTROL BOX,ELECTRICAL,VEHICULAR
944134

Frequently Asked Questions

What is NSN 5945-00-084-3427?

NSN 5945-00-084-3427 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What NSN replaces 5945-00-084-3427?

1 possible match (shared part number, not a government interchangeability claim): 2540-01-355-8942. Verify interchangeability with system specifications before substitution.

What are the specifications of 5945-00-084-3427?

Key specifications for 5945-00-084-3427: Mounting Facility Type and Quantity: 3 THREADED STUD(S) SINGLE MOUNTING FACILITY; Overall Height: 2.750 INCHES NOMINAL IN; Pile-Up Main Contact Form Arrangement: 1D1B; Main Contact Maximum Voltage Rating in Volts: 28.0 DC. 20 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-084-3427 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com