PartsTable TECHNICAL DATA SHEET
NSN 5945-00-028-0112Government record, cited

Relay, Electromagnetic5945-00-028-0112

NSN 5945-00-028-0112 · NIIN 000280112
FSC 5945 — Relays and Solenoids · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5945-00-028-0112 · 5945000280112 · NIIN 000280112 · 00-028-0112 · FSC 5945 Relays and Solenoids · E410-1128 · B13-4002A
Nearby stock numbers  ·
Features
  • Relay,electromagnetic — FSC 5945
  • Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
  • Mounting Facility Pattern: TRIANGLE SINGLE MOUNTING FACILITY
  • Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
  • Duty Type: CONTINUOUS
  • Unthreaded Mounting Hole Diameter: 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle: 1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
  • Winding DC Resistance Rating: 955.0 OHMS NOMINAL SINGLE WINDING
Identification
  • NSN: 5945-00-028-0112
  • NIIN: 000280112
  • FSC: 5945 — Relays and Solenoids
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Relay,electromagnetic, cataloged under National Stock Number 5945-00-028-0112, is classified within Federal Supply Class 5945 (Relays and Solenoids) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5945-00-028-0112
Item NameRelay,electromagnetic
FSC / FSG5945 / 59 — Relays and Solenoids
StatusACTIVE
Mounting Facility Type and Quantity3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY
Mounting Facility PatternTRIANGLE SINGLE MOUNTING FACILITY
Main Contact Load Current Rating at Maximum Rated Voltage10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
Duty TypeCONTINUOUS
Unthreaded Mounting Hole Diameter0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Center to Center Distance Between Mounting Facilities Parallel to the Altitude of an Isosceles Triangle1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Winding DC Resistance Rating955.0 OHMS NOMINAL SINGLE WINDING
Features ProvidedPOLARIZED
Coil Quantity1
Environmental ProtectionDUSTPROOF
Winding Quantity1
Operating Voltage Rating and Type at Specified Temp48.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
Terminal Type and Quantity14 PIN ALL FUNCTIONS
Nonpile-Up Main Contact Arrangement4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
E410-1128 3/2 Design control — primary reference
U.S. Government activity
B13-4002A 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5945 — Relays and Solenoids
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5945-00-000-0093
5945-00-000-0093 · Item name not on file
5945-00-001-1891
5945-00-001-1891 · Item name not on file
5945-00-001-2622
PLATE,RELAY
5945-00-001-2795
RELAY,ELECTROMAGNETIC
5945-00-001-2806
RELAY,REED
5945-00-001-2938
5945-00-001-2938 · Item name not on file
5945-00-001-3015
RELAY ASSEMBLY
5945-00-001-3016
PROTECTOR,OVERLOAD

Frequently Asked Questions

What is NSN 5945-00-028-0112?

NSN 5945-00-028-0112 is a Relay,electromagnetic, classified under FSC 5945, Relays and Solenoids. Status: active.

What are the specifications of 5945-00-028-0112?

Key specifications for 5945-00-028-0112: Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY; Overall Height: 1.025 INCHES MAXIMUM IN; Mounting Facility Pattern: TRIANGLE SINGLE MOUNTING FACILITY; Main Contact Load Current Rating at Maximum Rated Voltage: 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD. 14 specifications are documented in the U.S. Government catalog.

Is NSN 5945-00-028-0112 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com