The Connector,plug,electrical, cataloged under National Stock Number 5935-00-430-4107, is classified within Federal Supply Class 5935 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Bionex Medical Industries. Government technical data includes 28 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 11 commercial cross-references from 7 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5935-00-430-4107 |
| Primary Part Number | M39012-26-0503 |
| Item Name | Connector,plug,electrical |
| FSC / FSG | 5935 / 59 — No Item Name Available |
| Manufacturer | Bionex Medical Industries |
| Status | ACTIVE |
| Threaded Device Type | COUPLING FACILITY |
| Terminal Type | CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
| Terminal Location | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| Radio Frequency Type Contact Characteristic Impedance in Ohms | 50.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| Included Contact Type | COAXIAL PIN SINGLE MATING END SINGLE CONTACT GROUPING |
| Precious Material and Location | CONTACT SURFACE GOLD |
| Contact Surface Treatment | GOLD SINGLE MATING END SINGLE CONTACT GROUPING |
| Contact Removability | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| Shell Type | SOLID |
| Nominal Thread Length | 0.156 INCHES IN |
| Included Contact Quantity | 1 SINGLE MATING END SINGLE CONTACT GROUPING |
| Connector Locking Method | INTERNALLY THREADED COUPLING RING |
| Test Data Document | 81349-MIL-C-39012 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Precious Material and Weight | 0.005 GOLD GRAINS, TROY |
| Contact Surface Treatment Document and Classification | MIL-G-45204,TYPE 2,CLASS 2 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
| Precious Material | GOLD |
| Overall Diameter | 0.650 INCHES MAXIMUM IN |
| Environmental Protection | MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT WATER RESISTANT |
| Nominal Thread Size | 0.438 INCHES IN |
| Connector Cable Strain Relief Method | CRIMP TYPE |
| Thread Series Designator | UNEF |
| Contact Position Arrangement Style | TNC SINGLE MATING END |
| Specification/standard Data | 81349-MIL-C-39012/26 GOVERNMENT SPECIFICATION |
| Contact Maximum Frequency Rating | 11000.0 MEGAHERTZ SINGLE MATING END SINGLE CONTACT GROUPING |
| Mating End Quantity | 1 |
| Thread Direction | RIGHT-HAND |
| Thread Class | 2B |
| Body Style | STRAIGHT SHAPE, INTERNAL COUPLING |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| M39012-26-0503 | Bionex Medical Industries (USA) |
| KA-59-292 | Winchester Interconnect Corporation (USA) |
| M39012/26-503 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| 10135457 | Nimikkeistokeskus Ncb Finland (FIN) |
| 5935PL0194129 | Jednolity Indeks Materialowy - Uniform Material Index (POL) |
| MIL-PRF-39012/26 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| M39012/26-0503 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| M39012/26-503 | Raytheon Company Dba Raytheon Co (USA) |
| MIL-PRF-39012 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| MIL-C-39012/26 | Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M |
| M39012/26-0503 | Leonardo Spa Helicopters Division - Production Site (ITA) |
NSN 5935-00-430-4107 is a Connector,plug,electrical, manufactured by Bionex Medical Industries, classified under FSC 5935 (No Item Name Available). Status: active.
NSN 5935-00-430-4107 has 11 cross-referenced part numbers: M39012-26-0503 (Bionex Medical Industries), KA-59-292 (Winchester Interconnect Corporation), M39012/26-503 (Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M), 10135457 (Nimikkeistokeskus Ncb Finland), 5935PL0194129 (Jednolity Indeks Materialowy - Uniform Material Index) and 6 more.
There are 12 known substitutes for 5935-00-430-4107: 5935-00-089-4442, 5935-00-134-5342, 5935-00-136-6912 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for M39012-26-0503: Threaded Device Type: COUPLING FACILITY; Overall Length: 1.500 INCHES NOMINAL IN; Terminal Type: CRIMP SINGLE MATING END SINGLE CONTACT GROUPING; Terminal Location: BACK SINGLE MATING END SINGLE CONTACT GROUPING. 29 total characteristics are documented in the Federal Logistics Information System.