PartsTable TECHNICAL DATA SHEET
NSN 5930-01-357-6509Government record, cited

Switch, Thermostatic5930-01-357-6509

NSN 5930-01-357-6509 · NIIN 013576509
FSC 5930 — Switches · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5930-01-357-6509 · 5930013576509 · NIIN 013576509 · 01-357-6509 · FSC 5930 Switches · M24236/1-FKCJK · MIL-PRF-24236/1 · MIL-S-24236/1
Nearby stock numbers  ·
Features
  • Switch,thermostatic — FSC 5930
  • Body Diameter: 0.640 INCHES MAXIMUM IN
  • Frequency in Hertz: 60.0 FIRST VOLTAGE
  • Contact Action Stimulus: INCREASE
  • Terminal Type: TAB, SOLDER LUG
  • Mounting Facility Pattern: TWO POSITION IN-LINE
  • Contact Load Current Rating: 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE
  • Contact Load Current Rating: 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
Identification
  • NSN: 5930-01-357-6509
  • NIIN: 013576509
  • FSC: 5930 — Switches
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Switch,thermostatic, cataloged under National Stock Number 5930-01-357-6509, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5930-01-357-6509
Item NameSwitch,thermostatic
FSC / FSG5930 / 59 — Switches
StatusACTIVE
Body Diameter0.640 INCHES MAXIMUM IN
Frequency in Hertz60.0 FIRST VOLTAGE
Contact Action StimulusINCREASE
Terminal TypeTAB, SOLDER LUG
Mounting Facility PatternTWO POSITION IN-LINE
Contact Load Current Rating2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE
Contact Load Current Rating5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
Mounting MethodBRACKET(S) AND SLOT AND UNTHREADED HOLE(S)
Body Height0.260 INCHES MINIMUM AND 0.325 INCHES MAXIMUM IN
Unthreaded Mounting Hole Diameter0.140 INCHES NOMINAL IN
Style DesignatorDISC W/FLANGE
Temp Sensing Element TypeINTERNAL SENSOR
Features ProvidedHERMETICALLY SEALED CASE
Distance Between Mounting Facility Centers0.937 INCHES NOMINAL IN
Specification/standard Data81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION
Operating Temp Rating-65.0 FAHRENHEIT MINIMUM AND 500.0 FAHRENHEIT MAXIMUM DEGF
Nonpile-Up Contact Arrangement1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
Media for Which DesignedGAS OR LIQUID
Test Data Document81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Contact Stimulus Rating150.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 135.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
Contact AdjustabilityACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
Contact Voltage Rating in Volts28.0 DC AT SEA LEVEL SECOND VOLTAGE
Contact Voltage Rating in Volts115.0 AC AT SEA LEVEL FIRST VOLTAGE
Mounting Slot Width0.140 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
M24236/1-FKCJK 2/2 Government specification standardization
U.S. Government activity
MIL-PRF-24236/1 4/1 Identification reference
U.S. Government activity
MIL-S-24236/1 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5930 — Switches
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5930-00-000-0117
SWITCH,PRESSURE
5930-00-001-1407
5930-00-001-1407 · Item name not on file
5930-00-001-1890
SWITCH,SENSITIVE
5930-00-001-2571
SWITCH,ROTARY
5930-00-001-2575
5930-00-001-2575 · Item name not on file
5930-00-001-2580
5930-00-001-2580 · Item name not on file
5930-00-001-2608
5930-00-001-2608 · Item name not on file
5930-00-001-2609
5930-00-001-2609 · Item name not on file

Frequently Asked Questions

What is NSN 5930-01-357-6509?

NSN 5930-01-357-6509 is a Switch,thermostatic, classified under FSC 5930, Switches. Status: active.

What are the specifications of 5930-01-357-6509?

Key specifications for 5930-01-357-6509: Body Diameter: 0.640 INCHES MAXIMUM IN; Overall Height: 0.638 INCHES NOMINAL IN; Frequency in Hertz: 60.0 FIRST VOLTAGE; Contact Action Stimulus: INCREASE. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5930-01-357-6509 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.