The Switch,push, cataloged under National Stock Number 5930-01-288-0171, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. Government technical data includes 13 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5930-01-288-0171 |
| Item Name | Switch,push |
| FSC / FSG | 5930 / 59 — Switches |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Actuator Inscription | STOP STANCHIONS SINGLE ACTUATOR |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.620 INCHES NOMINAL IN |
| Body Height | 1.620 INCHES NOMINAL IN |
| Criticality Code Justification | FEAT |
| Nominal Thread Size | 0.164 INCHES IN |
| Nonpile-Up Contact Arrangement | 1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| Maximum Voltage Rating in Volts | 440.0 AC AND 355.0 DC |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.250 INCHES NOMINAL IN |
| Thread Quantity Per Inch | 32 |
| Terminal Type and Quantity | 4 TAB W/SCREW |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Contact Load Current Rating at Maximum Rated Voltage | 0.500 AMPERES INDUCTIVE DC AND 5.000 AMPERES INDUCTIVE AC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | Y |
| Reference | Meaning |
|---|---|
| 6981ED165-423 | 5/1 Secondary reference Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc |
| B554AF177 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5930-01-288-0171 is a Switch,push, classified under FSC 5930, Switches. Status: active.
Key specifications for 5930-01-288-0171: Inclosure Type: FULLY INCLOSED; Actuator Inscription: STOP STANCHIONS SINGLE ACTUATOR; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.620 INCHES NOMINAL IN; Body Height: 1.620 INCHES NOMINAL IN. 13 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.