PartsTable TECHNICAL DATA SHEET
NSN 5930-01-225-4948Government record, cited

Switch, Toggle5930-01-225-4948

NSN 5930-01-225-4948 · NIIN 012254948 · Part number 514A901P1
General Electric Co Medical Systems Div · FSC 5930 — Switches · FSG 59 — Electrical and Electronic Equipment Components · CAGE 24456
Government record, cited
NSN 5930-01-225-4948 — this item is cataloged by the U.S. Government under National Stock Number 5930-01-225-4948. Manufacturer of record part number: 514A901P1.
Also searched as  5930-01-225-4948 · 5930012254948 · NIIN 012254948 · 01-225-4948 · FSC 5930 Switches · CAGE 24456 · 514A901P1 · 8906K299
Nearby stock numbers  ·
Features
  • Switch,toggle — FSC 5930
  • Bushing Length: 0.468 INCHES NOMINAL IN
  • Actuator Diameter: 0.125 INCHES NOMINAL IN
  • Inclosure Type: FULLY INCLOSED
  • Actuator Position-Locking Relationship: UP POSITION LOCKED IN AND CENTER POSITION NO LOCKING ACTION AND DOWN POSITION LOCKED IN AND OUT
  • Body Style: BUSHING MOUNT
  • Actuator Style: ROUND
  • Mounting Method: STUD(S)
Identification
  • NSN: 5930-01-225-4948
  • NIIN: 012254948
  • FSC: 5930 — Switches
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 514A901P1
  • Manufacturer: General Electric Co Medical Systems Div
General Description

The Switch,toggle, cataloged under National Stock Number 5930-01-225-4948, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. The manufacturer of record is General Electric Co Medical Systems Div. Government technical data includes 18 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5930-01-225-4948
Primary Part Number514A901P1
Item NameSwitch,toggle
FSC / FSG5930 / 59 — Switches
ManufacturerGeneral Electric Co Medical Systems Div
StatusACTIVE
Bushing Length0.468 INCHES NOMINAL IN
Actuator Diameter0.125 INCHES NOMINAL IN
Inclosure TypeFULLY INCLOSED
Actuator Position-Locking RelationshipUP POSITION LOCKED IN AND CENTER POSITION NO LOCKING ACTION AND DOWN POSITION LOCKED IN AND OUT
Body StyleBUSHING MOUNT
Actuator StyleROUND
Mounting MethodSTUD(S)
Body Width0.812 INCHES MAXIMUM IN
Body Height0.812 INCHES NOMINAL IN
Mounting Surface to Terminal End Distance1.250 INCHES MAXIMUM IN
Actuator Position-Action RelationshipUP POSITION MOMENTARY AND CENTER POSITION MAINTAINED AND DOWN POSITION MAINTAINED
Body Length1.375 INCHES MAXIMUM IN
Nonpile-Up Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT
Maximum Voltage Rating in Volts250.0 AC
MaterialPLASTIC CASE
Terminal Type and Quantity6 QUICK DISCONNECT, MALE
Actuator Height0.562 INCHES NOMINAL IN
Contact Load Current Rating at Maximum Rated Voltage3.000 AMPERES RESISTIVE AC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
514A901P1 PRIMARY General Electric Co Medical Systems Div (USA)
Reference documents
ReferenceMeaning
8906K299 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5930 — Switches
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5930-00-000-0117
SWITCH,PRESSURE
5930-00-001-1407
5930-00-001-1407 · Item name not on file
5930-00-001-1890
SWITCH,SENSITIVE
5930-00-001-2571
SWITCH,ROTARY
5930-00-001-2575
5930-00-001-2575 · Item name not on file
5930-00-001-2580
5930-00-001-2580 · Item name not on file
5930-00-001-2608
5930-00-001-2608 · Item name not on file
5930-00-001-2609
5930-00-001-2609 · Item name not on file

Frequently Asked Questions

What is NSN 5930-01-225-4948?

NSN 5930-01-225-4948 is a Switch,toggle, manufactured by General Electric Co Medical Systems Div, classified under FSC 5930, Switches. Status: active.

What part numbers are listed for NSN 5930-01-225-4948?

NSN 5930-01-225-4948 has 1 manufacturer part number on file: 514A901P1 (General Electric Co Medical Systems Div).

What are the specifications of 514A901P1?

Key specifications for 514A901P1: Bushing Length: 0.468 INCHES NOMINAL IN; Actuator Diameter: 0.125 INCHES NOMINAL IN; Inclosure Type: FULLY INCLOSED; Actuator Position-Locking Relationship: UP POSITION LOCKED IN AND CENTER POSITION NO LOCKING ACTION AND DOWN POSITION LOCKED IN AND OUT. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5930-01-225-4948 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.