PartsTable TECHNICAL DATA SHEET
NSN 5930-01-174-8592Government record, cited

Switch, Pressure5930-01-174-8592

NSN 5930-01-174-8592 · NIIN 011748592 · Part number MMP92049-1
Drs Environmental Systems Inc · FSC 5930 — Switches · FSG 59 — Electrical and Electronic Equipment Components · CAGE 5RQL2
Government record, cited
NSN 5930-01-174-8592 — this item is cataloged by the U.S. Government under National Stock Number 5930-01-174-8592. Manufacturer of record part number: MMP92049-1.
Also searched as  5930-01-174-8592 · 5930011748592 · NIIN 011748592 · 01-174-8592 · FSC 5930 Switches · CAGE 5RQL2 · MMP92049-1 · P28DA-140 · P28DA-140
Nearby stock numbers  ·
Features
  • Switch,pressure — FSC 5930
  • Contact Action Stimulus: INCREASE
  • Terminal Type: SCREW
  • Mounting Facility Pattern: TWO POSITION IN-LINE
  • Contact Load Current Rating: 3.125 AMPERES RESISTIVE LOAD SECOND VOLTAGE
  • Contact Load Current Rating: 6.25 AMPERES RESISTIVE LOAD FIRST VOLTAGE
  • Mounting Method: BRACKET(S) AND THREADED HOLE(S)
  • Criticality Code Justification: FEAT
Identification
  • NSN: 5930-01-174-8592
  • NIIN: 011748592
  • FSC: 5930 — Switches
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: MMP92049-1
  • Manufacturer: Drs Environmental Systems Inc
General Description

The Switch,pressure, cataloged under National Stock Number 5930-01-174-8592, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Drs Environmental Systems Inc. Government technical data includes 21 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5930-01-174-8592
Primary Part NumberMMP92049-1
Item NameSwitch,pressure
FSC / FSG5930 / 59 — Switches
ManufacturerDrs Environmental Systems Inc
StatusACTIVE
Contact Action StimulusINCREASE
Terminal TypeSCREW
Mounting Facility PatternTWO POSITION IN-LINE
Contact Load Current Rating3.125 AMPERES RESISTIVE LOAD SECOND VOLTAGE
Contact Load Current Rating6.25 AMPERES RESISTIVE LOAD FIRST VOLTAGE
Mounting MethodBRACKET(S) AND THREADED HOLE(S)
Criticality Code JustificationFEAT
Outside Diameter0.250 INCHES NOMINAL FIRST CONNECTION IN
Pressure Switch TypeDIFFERENTIAL
Features ProvidedMANUAL RESET BUTTON
Distance Between Mounting Facility Centers1.000 INCHES NOMINAL IN
Nominal Thread Size0.190 INCHES ALL THREADED HOLE IN
Pressure Connector TypeFLARED, THREADED EXTERNAL ALL CONNECTIONS
Nonpile-Up Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Media for Which DesignedLIQUID
Thread Class2B ALL THREADED HOLE
Contact Stimulus Rating70.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH GAGE
Thread Series DesignatorUNF ALL THREADED HOLE
Contact AdjustabilityACTUATION POINT NOT ADJUSTABLE, MANUAL RESET
Contact Voltage Rating in Volts240.0 AC AT SEA LEVEL SECOND VOLTAGE
Contact Voltage Rating in Volts120.0 AC AT SEA LEVEL FIRST VOLTAGE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeY
Cross-Reference Index
Part NumberManufacturer
P28DA-140 Johnson Controls, Inc Div Building Efficiency (USA)
MMP92049-1 PRIMARY Drs Environmental Systems Inc (USA)
Reference documents
ReferenceMeaning
MMP92049-1 3/9 Design control — primary reference
U.S. Government activity
P28DA-140 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5930 — Switches
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5930-00-000-0117
SWITCH,PRESSURE
5930-00-001-1407
5930-00-001-1407 · Item name not on file
5930-00-001-1890
SWITCH,SENSITIVE
5930-00-001-2571
SWITCH,ROTARY
5930-00-001-2575
5930-00-001-2575 · Item name not on file
5930-00-001-2580
5930-00-001-2580 · Item name not on file
5930-00-001-2608
5930-00-001-2608 · Item name not on file
5930-00-001-2609
5930-00-001-2609 · Item name not on file

Frequently Asked Questions

What is NSN 5930-01-174-8592?

NSN 5930-01-174-8592 is a Switch,pressure, manufactured by Drs Environmental Systems Inc, classified under FSC 5930, Switches. Status: active.

What part numbers are listed for NSN 5930-01-174-8592?

NSN 5930-01-174-8592 has 2 manufacturer part numbers on file: P28DA-140 (Johnson Controls, Inc Div Building Efficiency), MMP92049-1 (Drs Environmental Systems Inc).

What are the specifications of MMP92049-1?

Key specifications for MMP92049-1: Overall Height: 2.290 INCHES NOMINAL IN; Contact Action Stimulus: INCREASE; Terminal Type: SCREW; Mounting Facility Pattern: TWO POSITION IN-LINE. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5930-01-174-8592 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com