PartsTable TECHNICAL DATA SHEET
NSN 5930-01-135-4053Government record, cited

Switch, Rotary5930-01-135-4053

NSN 5930-01-135-4053 · NIIN 011354053 · Part number 2600344
Fluke Biomedical Corporation · FSC 5930 — Switches · FSG 59 — Electrical and Electronic Equipment Components · CAGE 34511
Government record, cited
NSN 5930-01-135-4053 — this item is cataloged by the U.S. Government under National Stock Number 5930-01-135-4053. Manufacturer of record part number: 2600344.
Also searched as  5930-01-135-4053 · 5930011354053 · NIIN 011354053 · 01-135-4053 · FSC 5930 Switches · CAGE 34511 · 2600344
Nearby stock numbers  ·
Features
  • Switch,rotary — FSC 5930
  • Shaft Type: ROUND FIRST ACTUATOR
  • Shaft Type: ROUND, HOLLOWED SECOND ACTUATOR
  • Shaft Diameter: 0.250 INCHES NOMINAL SECOND ACTUATOR IN
  • Shaft Diameter: 0.125 INCHES NOMINAL FIRST ACTUATOR IN
  • Switch Contact Basic Design: NONPILE-UP NONSYMMETRICAL
  • Nonturn Device Radius: 0.531 INCHES NOMINAL AT 3:00 OCLOCK IN
  • Nonturn Device Radius: 0.531 INCHES NOMINAL AT 9:00 OCLOCK IN
Identification
  • NSN: 5930-01-135-4053
  • NIIN: 011354053
  • FSC: 5930 — Switches
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 2600344
  • Manufacturer: Fluke Biomedical Corporation
General Description

The Switch,rotary, cataloged under National Stock Number 5930-01-135-4053, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Fluke Biomedical Corporation. Government technical data includes 27 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5930-01-135-4053
Primary Part Number2600344
Item NameSwitch,rotary
FSC / FSG5930 / 59 — Switches
ManufacturerFluke Biomedical Corporation
StatusACTIVE
Shaft TypeROUND FIRST ACTUATOR
Shaft TypeROUND, HOLLOWED SECOND ACTUATOR
Shaft Diameter0.250 INCHES NOMINAL SECOND ACTUATOR IN
Shaft Diameter0.125 INCHES NOMINAL FIRST ACTUATOR IN
Switch Contact Basic DesignNONPILE-UP NONSYMMETRICAL
Nonturn Device Radius0.531 INCHES NOMINAL AT 3:00 OCLOCK IN
Nonturn Device Radius0.531 INCHES NOMINAL AT 9:00 OCLOCK IN
Terminal TypeTAB, SOLDER LUG
Precious MaterialSILVER
Contact Load Current Rating250.0 MILLIAMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL
Contact Load Current Rating750.0 MILLIAMPERES RESISTIVE LOAD AC AT SEA LEVEL
Contact Load Current Rating500.0 MILLIAMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL
Mounting MethodTHREADED BUSHING SINGLE MOUNTING FACILITY
Thread Length0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY IN
Style DesignatorCIRCULAR WAFER, BUSHING MOUNT
Individual Section Quantity10
Nonturn Device TypeTAB AT 9:00 OCLOCK
Nonturn Device TypeTAB AT 3:00 OCLOCK
Features ProvidedVARIABLE RESISTOR PROVISIONS
Nominal Thread Size0.375 INCHES SINGLE MOUNTING FACILITY IN
Shaft Length0.375 INCHES NOMINAL SECOND ACTUATOR IN
Shaft Length0.375 INCHES NOMINAL FIRST ACTUATOR IN
Switch Actuator Stop Device TypeADJUSTABLE STOP SINGLE ACTUATOR
Contact Voltage Rating in Volts250.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL
Contact Voltage Rating in Volts125.0 AC AT SEA LEVEL
Contact Voltage Rating in Volts125.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL
Precious Material and LocationCONTACT SURFACES SILVER
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
2600344 PRIMARY Fluke Biomedical Corporation (USA)

Frequently Asked Questions

What is NSN 5930-01-135-4053?

NSN 5930-01-135-4053 is a Switch,rotary, manufactured by Fluke Biomedical Corporation, classified under FSC 5930, Switches. Status: active.

What part numbers are listed for NSN 5930-01-135-4053?

NSN 5930-01-135-4053 has 1 manufacturer part number on file: 2600344 (Fluke Biomedical Corporation).

What are the specifications of 2600344?

Key specifications for 2600344: Shaft Type: ROUND FIRST ACTUATOR; Shaft Type: ROUND, HOLLOWED SECOND ACTUATOR; Overall Height: 1.312 INCHES NOMINAL IN; Shaft Diameter: 0.250 INCHES NOMINAL SECOND ACTUATOR IN. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5930-01-135-4053 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com