The Switch,sensitive, cataloged under National Stock Number 5930-01-100-4116, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5930-01-100-4116 |
| Item Name | Switch,sensitive |
| FSC / FSG | 5930 / 59 — Switches |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Body Style | HOLE MOUNTED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 0.875 INCHES NOMINAL IN |
| Actuator Style | RECTANGULAR |
| Mounting Method | UNTHREADED HOLE(S) |
| Actuator Width | 0.165 INCHES NOMINAL IN |
| Switch Actuating Force | 50.0 GRAMS MAXIMUM G |
| Body Width | 0.400 INCHES NOMINAL IN |
| Body Height | 0.625 INCHES NOMINAL IN |
| Switch Release Force | 5.0 GRAMS MINIMUM G |
| Unthreaded Mounting Hole Diameter | 0.126 INCHES NOMINAL IN |
| Center to Center Distance Between Mounting Facilities Parallel to Height | 0.406 INCHES NOMINAL IN |
| Body Length | 1.094 INCHES NOMINAL IN |
| Actuator Length | 0.110 INCHES NOMINAL IN |
| Actuator Movement | 0.047 PRETRAVEL INCHES MAXIMUM AND 0.050 OVERTRAVEL INCHES MINIMUM AND 0.002 DIFFERENTIAL INCHES MINIMUM |
| Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| Maximum Voltage Rating in Volts | 277.0 AC |
| Material | PLASTIC CASE |
| Terminal Type and Quantity | 3 TAB, SOLDER LUG |
| Actuator Height | 0.172 INCHES NOMINAL IN |
| Contact Load Current Rating at Maximum Rated Voltage | 5.000 AMPERES RESISTIVE AC |
| Actuator Free Position Height | 0.578 INCHES NOMINAL IN |
| Hazardous Locations/environmental Protection | DUSTPROOF |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 09R014WS | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| V3-2101-D8 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5930-01-100-4116 is a Switch,sensitive, classified under FSC 5930, Switches. Status: active.
Key specifications for 5930-01-100-4116: Inclosure Type: FULLY INCLOSED; Body Style: HOLE MOUNTED; Center to Center Distance Between Mounting Facilities Parallel to Length: 0.875 INCHES NOMINAL IN; Actuator Style: RECTANGULAR. 23 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.