The Switch,thermostatic, cataloged under National Stock Number 5930-00-929-1576, is classified within Federal Supply Class 5930 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings). Government technical data includes 23 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 3 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 11 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5930-00-929-1576 |
| Primary Part Number | DMS 86108B |
| Item Name | Switch,thermostatic |
| FSC / FSG | 5930 / 59 — No Item Name Available |
| Manufacturer | Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) |
| Status | ACTIVE |
| Terminal Type | WIRE LEAD |
| Mounting Facility Pattern | TWO POSITION IN-LINE |
| Temp Sensing Element Type | CAPILLARY TUBE-BULB |
| Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| Contact Adjustability | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| Contact Load Current Rating | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| Contact Adjustment Range | +75.00 TO 95.00 ACTUATION POINT DEGREES FAHRENHEIT AND +75.00 TO 95.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| Style Designator | RECTANGULAR |
| Contact Adjustment Type | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE |
| Contact Voltage Rating in Volts | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
| Media for Which Designed | GAS |
| Body Height | 2.750 INCHES NOMINAL IN |
| Contact Voltage Rating in Volts | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
| Capillary Tube Length | 6.000 INCHES NOMINAL IN |
| Mounting Method | UNTHREADED HOLE(S) |
| Nonpile-Up Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| Distance Between Mounting Facility Centers | 2.250 INCHES NOMINAL IN |
| Features Provided | TUBING END SEAL CONNECTION |
| Bulb Length | 4.188 INCHES NOMINAL IN |
| Contact Action Stimulus | INCREASE |
| Unthreaded Mounting Hole Diameter | 0.219 INCHES NOMINAL IN |
| Bulb Diameter | 0.750 INCHES NOMINAL IN |
| Hazardous Locations/environmental Protection | DUSTPROOF |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| DMS 86108B | Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) (USA) |
| 458310 | Eastman Kodak Co (USA) |
| E7M0DEL6399 | United Electric Controls Company (USA) |
NSN 5930-00-929-1576 is a Switch,thermostatic, manufactured by Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings), classified under FSC 5930 (No Item Name Available). Status: active.
NSN 5930-00-929-1576 has 3 cross-referenced part numbers: DMS 86108B (Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)), 458310 (Eastman Kodak Co), E7M0DEL6399 (United Electric Controls Company).
There are 11 known substitutes for 5930-00-929-1576: 5930-00-184-6026, 4240-00-421-5798, 5930-00-422-0514 and 8 more. Verify interchangeability with system specifications before substitution.
Key specifications for DMS 86108B: Terminal Type: WIRE LEAD; Mounting Facility Pattern: TWO POSITION IN-LINE; Temp Sensing Element Type: CAPILLARY TUBE-BULB; Contact Load Current Rating: 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE. 27 total characteristics are documented in the Federal Logistics Information System.