The Switch,thermostatic, cataloged under National Stock Number 5930-00-263-2972, is classified within Federal Supply Class 5930 (Switches) of the Electrical and Electronic Equipment Components group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5930-00-263-2972 |
| Item Name | Switch,thermostatic |
| FSC / FSG | 5930 / 59 — Switches |
| Status | ACTIVE |
| Contact Action Stimulus | INCREASE |
| Terminal Type | QUICK DISCONNECT, MALE |
| Mounting Facility Pattern | TWO POSITION IN-LINE |
| Contact Load Current Rating | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| Contact Load Current Rating | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| Mounting Method | BRACKET(S) AND UNTHREADED HOLE(S) |
| Contact Adjustment Range | -17.30 TO 26.00 ACTUATION POINT DEGREES FAHRENHEIT AND -17.30 TO 26.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| Body Width | 1.000 INCHES NOMINAL IN |
| Body Height | 1.470 INCHES NOMINAL IN |
| Unthreaded Mounting Hole Diameter | 0.218 INCHES NOMINAL IN |
| Style Designator | RECTANGULAR W/BRACKET |
| Temp Sensing Element Type | CAPILLARY TUBE |
| Contact Adjustment Type | EXTERNAL DEACTUATION POINT SCREW AND EXTERNAL ACTUATION POINT SCREW |
| Features Provided | CAPILLARY TUBE END SEAL CONNECTION |
| Distance Between Mounting Facility Centers | 3.000 INCHES NOMINAL IN |
| Capillary Tube Length | 18.000 INCHES NOMINAL IN |
| Body Length | 1.500 INCHES NOMINAL IN |
| Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| Media for Which Designed | GAS OR LIQUID |
| Contact Adjustability | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| Contact Voltage Rating in Volts | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
| Contact Voltage Rating in Volts | 120.0 AC AT SEA LEVEL SECOND VOLTAGE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 1969SXS | 5/9 Secondary reference U.S. Government activity |
| 3ART5AE6 | 5/9 Secondary reference General Electric Co Appliance Control Dept |
| 9530N511 | 5/9 Secondary reference Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc |
| C36150-2 | 3/9 Design control — primary reference U.S. Government activity |
| 1C36150-2 | 5/9 Secondary reference U.S. Government activity |
| 72C36150-2 | 5/9 Secondary reference U.S. Government activity |
NSN 5930-00-263-2972 is a Switch,thermostatic, classified under FSC 5930, Switches. Status: active.
Key specifications for 5930-00-263-2972: Overall Height: 2.638 INCHES NOMINAL IN; Contact Action Stimulus: INCREASE; Terminal Type: QUICK DISCONNECT, MALE; Mounting Facility Pattern: TWO POSITION IN-LINE. 22 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.