The Switch,toggle, cataloged under National Stock Number 5930-00-108-7019, is classified within Federal Supply Class 5930 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Hewlett-Packard Co Waltham Div. Government technical data includes 18 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 14 commercial cross-references from 10 manufacturers, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5930-00-108-7019 |
| Primary Part Number | 62D26 |
| Item Name | Switch,toggle |
| FSC / FSG | 5930 / 59 — No Item Name Available |
| Manufacturer | Hewlett-Packard Co Waltham Div |
| Status | CANCELLED |
| Actuator Style | ROUND |
| Thread Quantity Per Inch | 32 |
| Inclosure Type | FULLY INCLOSED |
| Body Style | BUSHING MOUNT |
| Actuator Position-Action Relationship | UP POSITION MAINTAINED AND DOWN POSITION MOMENTARY AND CENTER POSITION MAINTAINED |
| Contact Load Current Rating at Maximum Rated Voltage | 20.000 AMPERES RESISTIVE DC AND 10.000 AMPERES INDUCTIVE DC AND 4.000 AMPERES LAMP DC AND 16.000 AMPERES MOTOR DC AND 11.000 AMPERES RESISTIVE AC AND 7.500 AMPERES INDUCTIVE AC AND 2.000 AMPERES LAMP AC AND 7.000 AMPERES MOTOR AC |
| Terminal Type and Quantity | 3 TAB, SOLDER LUG |
| Actuator Diameter | 0.125 INCHES NOMINAL IN |
| Body Width | 0.625 INCHES NOMINAL IN |
| Nonpile-Up Contact Arrangement | 1 POLE, DOUBLE THROW, THREE POSITIONS MAINTAINED SINGLE SWITCH UNIT |
| Switch Actuator Quantity | 1 |
| Bushing Length | 0.469 INCHES NOMINAL IN |
| Thread Series Designator | UNS |
| Body Length | 1.125 INCHES NOMINAL IN |
| Actuator Height | 0.688 INCHES NOMINAL IN |
| Body Height | 1.094 INCHES NOMINAL IN |
| Maximum Voltage Rating in Volts | 125.0 AC AND 28.0 DC |
| Nominal Thread Size | 0.469 INCHES IN |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 62D26 | Hewlett-Packard Co Waltham Div (USA) |
| 4620015153 | Thales Deutschland Gmbh Div Customer Services (DEU) |
| 8815K6 | Eaton Corp Opns & Technical Center (USA) |
| 7508K5 | Eaton Corp Opns & Technical Center (USA) |
| 8815K6 | Safran Power Usa, Llc (USA) |
| 62D26 | Philips North America Llc Dba Philips Healthcare (USA) |
| 488625-124 | L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc. (USA) |
| MS35058-19 | Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M |
| JANS23TYPEST42H | Joint Army-Navy Specifications Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M |
| P7768428REV3PC8 | General Electric Company (USA) |
| 7508K5 | Safran Power Usa, Llc (USA) |
| ST42H | Joint Army-Navy Specifications Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M |
| SW120-181 | Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier (USA) |
| P7768428P8 | General Electric Company (USA) |
NSN 5930-00-108-7019 is a Switch,toggle, manufactured by Hewlett-Packard Co Waltham Div, classified under FSC 5930 (No Item Name Available). Status: cancelled.
NSN 5930-00-108-7019 has 14 cross-referenced part numbers: 62D26 (Hewlett-Packard Co Waltham Div), 4620015153 (Thales Deutschland Gmbh Div Customer Services), 8815K6 (Eaton Corp Opns & Technical Center), 7508K5 (Eaton Corp Opns & Technical Center), 8815K6 (Safran Power Usa, Llc) and 9 more.
There are 2 known substitutes for 5930-00-108-7019: 5930-00-655-1523, 5930-01-089-6653. Verify interchangeability with system specifications before substitution.
Key specifications for 62D26: Actuator Style: ROUND; Thread Quantity Per Inch: 32; Inclosure Type: FULLY INCLOSED; Body Style: BUSHING MOUNT. 18 total characteristics are documented in the Federal Logistics Information System.
NSN 5930-00-108-7019 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.