The Circuit Breaker, cataloged under National Stock Number 5925-01-699-5647, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-699-5647 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | DUAL COIL ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 230.0 AC AND 80.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) |
| Ultimate Trip Time Per Pole in Seconds | 52.0 NOMINAL ALL LOCATIONS |
| Switch Terminal Type | TAB W/SCREW |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 62.4 GRAMS NOMINAL G |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 230.0 AC AND 80.0 DC |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 42.164 MILLIMETERS NOMINAL MM |
| Thread Pitch in Millimeters | 0.7938 |
| Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
| Body Width | 19.05 MILLIMETERS NOMINAL MM |
| Body Height | 42.85 MILLIMETERS NOMINAL MM |
| Unthreaded Mounting Hole Diameter | 3.96 MILLIMETERS NOMINAL MM |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 52.705 MILLIMETERS MAXIMUM MM |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC AND 30.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 30.0 AC AND 30.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.1380 INCHES IN |
| Body Length | 50.8 MILLIMETERS NOMINAL MM |
| Trip Delay Time in Seconds Per Rated Continuous Current | 52.0 NOMINAL AT 100 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Current Rating and Type in Amps | 30.0 AC AND 30.0 DC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IUG2-41445-30 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-699-5647 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-699-5647: Reset Method: MANUAL; Internal Trip Release Configuration: DUAL COIL ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC AND 80.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S). 26 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.