The Circuit Breaker, cataloged under National Stock Number 5925-01-694-9439, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-694-9439 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | AUTOMATIC |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 DC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 DC THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 80.0 DC FIRST LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60 ALL LOCATIONS |
| Unpackaged Unit Weight | 100.0 GRAMS NOMINAL G |
| Body Style | SINGLE POLE TYPE |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 100.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Nominal Thread Size | 0.25 INCHES IN |
| Thread Quantity Per Inch | 20.0 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 THREADED STUD |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AM1R-B8-AC97-D-A-100-5 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-694-9439 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-694-9439: Reset Method: AUTOMATIC; Operating Voltage Type and Rating Per Pole in Volts: 240.0 DC SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 DC THIRD LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC FIRST LOCATION. 17 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.