PartsTable TECHNICAL DATA SHEET
NSN 5925-01-693-6859Government record, cited

Circuit Breaker5925-01-693-6859

NSN 5925-01-693-6859 · NIIN 016936859
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-693-6859 · 5925016936859 · NIIN 016936859 · 01-693-6859 · FSC 5925 Circuit Breakers · IUGN66-1REC4-62-40.0-A · IUGN66-1REC4-62-40.0-A
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.495 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Ultimate Trip Time Per Pole in Seconds: 0.01 MINIMUM AND 0.25 MAXIMUM ALL LOCATIONS
Identification
  • NSN: 5925-01-693-6859
  • NIIN: 016936859
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-693-6859, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-693-6859
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.495 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts80.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity3 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Ultimate Trip Time Per Pole in Seconds0.01 MINIMUM AND 0.25 MAXIMUM ALL LOCATIONS
Frequency in Hertz60 ALL LOCATIONS
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent1000.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length0.656 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.515 INCHES MAXIMUM IN
Unthreaded Mounting Hole Diameter0.156 INCHES NOMINAL IN
Pole Quantity2
Mounting Surface to Terminal End Distance2.256 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole40.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps50.0 DC ALL LOCATIONS
Body Length2.00 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current10.0 MINIMUM AT 125 PCT AND 120.0 MAXIMUM AT 125 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.750 INCHES NOMINAL IN
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity5 QUICK DISCONNECT, MALE
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
IUGN66-1REC4-62-40.0-A 5/9 Secondary reference
U.S. Government activity
IUGN66-1REC4-62-40.0-A 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-693-6859?

NSN 5925-01-693-6859 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-693-6859?

Key specifications for 5925-01-693-6859: Bushing Length: 0.495 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 80.0 DC ALL LOCATIONS. 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-693-6859 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com