The Circuit Breaker, cataloged under National Stock Number 5925-01-693-1328, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-693-1328 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 30.0 DC AND 120.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED STUD(S) |
| Thread Tolerance Class | 2A EXTERNAL A |
| Ultimate Trip Time Per Pole in Seconds | 55.000 NOMINAL SINGLE LOCATION |
| Unpackaged Unit Weight | 49.000 GRAMS NOMINAL G |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 135.000 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 60.0 AMPERES AC SINGLE LOCATION |
| Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
| Nominal Thread Size | 0.1891 INCHES IN |
| Manual Actuator Type and Quantity | 1 PUSH BUTTON |
| Inclosure Protection Type for Which Designed | MOISTURE PROOF AND DUSTPROOF AND VAPORTIGHT AND WEATHERPROOF |
| Thread Quantity Per Inch | 32 |
| Terminal Type and Quantity | 2 THREADED STUD |
| Thread Series Designator | UNF |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 7854-26-60 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-693-1328 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-693-1328: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 30.0 DC AND 120.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED STUD(S); Overall Height: 1.469 INCHES MINIMUM AND 1.531 INCHES MAXIMUM IN. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.