The Circuit Breaker, cataloged under National Stock Number 5925-01-688-1995, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Carling Technologies, Inc Dba Carlingswitch. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-688-1995 |
| Primary Part Number | MS1-B-14-620-C-1CA-A-C |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Carling Technologies, Inc Dba Carlingswitch |
| Status | ACTIVE |
| Operating Voltage Type and Rating Per Pole in Volts | 65.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Body Style | SINGLE POLE TYPE |
| Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Terminal Type and Quantity | 4 SCREW BASE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| MS1-B-14-620-C-1CA-A-C PRIMARY | Carling Technologies, Inc Dba Carlingswitch (USA) |
NSN 5925-01-688-1995 is a Circuit Breaker, manufactured by Carling Technologies, Inc Dba Carlingswitch, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-688-1995 has 1 manufacturer part number on file: MS1-B-14-620-C-1CA-A-C (Carling Technologies, Inc Dba Carlingswitch).
Key specifications for MS1-B-14-620-C-1CA-A-C: Operating Voltage Type and Rating Per Pole in Volts: 65.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S); Body Style: SINGLE POLE TYPE; Circuit Protection Type: OVERVOLTAGE ALL LOCATIONS. 8 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.